M204.0035
Jump to navigation
Jump to search
M204.0035 Variable parameters may not be reset
In a continuation request (after a MORE command), either the length of a string was specified longer than the maximum length defined during the basic request, or the number of decimal places was changed.
Response: If a longer string is required, either make the string longer in the basic request or use a different %variable in the continuation request. If the number of decimal places must change, use a different %variable. Then retry the request.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
ECHO | Displays the line that caused the error |
COMPILE | Compilation error |