M204.0089  No I​/​O allowed on terminal while process-to-process is in effect

The DEFINE PROCESS command, for this partner process, specified TERMINAL=REMOTE. After an OPEN PROCESS statement is issued, this partner process owns the terminal, and Model 204 cannot perform I/O to this terminal until a CLOSE PROCESS statement is issued.

Response: Change the DEFINE PROCESS command parameter to TERMINAL=LOCAL, or remove the SOUL statements between the OPEN PROCESS and CLOSE PROCESS statements that are causing an I/O to the terminal.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter