M204.0338

From m204wiki
Jump to navigation Jump to search

M204.0338  Incorrect format for CCASTAT

Model 204 encountered an end-of-file condition reading the first record in the password table. The password table is empty or Model 204 is incorrectly reading the table.

System manager response: If the data set is empty, run the ZBLDTAB utility to create the password table or rerun with Model 204 pointing to a valid password table. Contact Technical Support if the data set contains a valid password table.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter

Back to list of messages