M204.0461 Wrong page write attempt on file fileName
In trying to write a file page from a disk buffer to disk, Model 204 detected the disk buffer monitor hash field cell does not match the table/page number in the file to which it is to write. Model 204 takes a snap dump and terminates the run.
Response: Notify your system manager.
System manager response: Contact Technical Support and have the following documentation available:
- Audit trail
- Snap(s)
- SOUL request for the user who received the message
Message attributes:
RETCODEO=96 | Sets online return code |
---|---|
RETCODEB=96 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
SNAP | Generates a CCASNAP for the run |
DUMP | Generates a SYSUDUMP for the entire Model 204 region |