M204.0637
Jump to navigation
Jump to search
M204.0637 No room for record description
During the opening of a Model 204 file, the record description, which exists if any fields contain the preallocated attribute, is read into memory. The message is produced if insufficient storage exists to hold the entire record description. The file is opened successfully, but any attempt to reference a preallocated field will generate an error.
Response: Notify your file manager and system manager. Depending on your application, you may not be able use the file. Wait a few minutes for other users to finish their tasks, and try again.
System manager response: Increasing the value of the SPCORE parameter will prevent this problem from occurring in future Model 204 runs.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |