M204.0695
Jump to navigation
Jump to search
M204.0695 Invalid binary input
Model 204 has detected a binary field that exceeds four bytes in length. The high-order four bytes are stored as the binary number.
Response: Correct the FLOD instructions or the source data, and rerun the job. If this FLOD operation updates an existing file, the input stream will have to be edited to account for the previous updates that may have occurred prior to the error.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |