M204.0758 Insufficient storage for message
You issued one of the Model 204 commands that requires the specification of message text (for example, MSG, WARN, or BROADCAST). Model 204 does not have enough storage to process this message text.
Response: Notify your system manager.
System manager response: Increase the amount of general memory available to Model 204 by increasing the value of SPCORE or by decreasing the value of MAXBUF. Both parameters are specified on the User 0 parameter line. You may also have to increase the memory available to the job by changing the REGION parameter in z/OS, increasing the virtual machine size in CMS, or increasing the partition size in z/VSE.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |
NOTERM | Does not display the message on the user's terminal |
OPR | Writes the message to the (operator) console |
SAVE | Saves the message in the VIEW ERRORS table |