M204.0961
Jump to navigation
Jump to search
M204.0961 Unable to force signon checkpoint for job jobname
A batch job sign-on checkpoint was desired, so a checkpoint was attempted. However, CPSORT attempts to take the checkpoint were exceeded; so no checkpoint was taken.
System manager response: You may want to review the use of checkpointing within your Model 204 system; see Checkpoints: Storing before-images of changed pages for further information.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=0 | Sets batch (single user) return code |
CLASS=I | Information class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |