M204.1058
Jump to navigation
Jump to search
M204.1058 token out of token2 output buffers are active
This is an informational message generated by the MONITOR VTAM command. The message displays the number of output buffers in use when the MONITOR VTAM command was issued.
System manager response: This information is useful in tuning the Model 204 Online system. If the percentage of active buffers is exceptionally high, increase the NOUTBUF parameter. If the percentage is low, decrease the NOUTBUF parameter. This parameter is on the User 0 line of the CCAIN parameters in the Model 204 Online job. Correct, and rerun.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=0 | Sets batch (single user) return code |
CLASS=I | Information class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |