M204.1323 Block of length token read from token2 with a block descriptor word which specifies a length of token3
For this variable-length data set, the length specified in the block descriptor word (BDW) is not consistent with the length of the block actually read.
System manager response: Verify the block size that you have specified for the named data set. Make sure you have added eight bytes (four for the block descriptor word and four for the record descriptor word) to the maximum record length. Correct the error and rerun Model 204 if the data set is crucial to the run.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITAD | Writes the message with line type AD to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |