M204.1804

From m204wiki
Jump to navigation Jump to search

M204.1804  Insufficient CSA storage for cross-memory control block allocation

The Model 204 Cross-Memory Services SVC was unable to obtain sufficient storage from CSA to build a cross-memory control block.

System manager response: Restart Model 204 (more CSA storage may become available), or do not use the Timer PC. CSA storage may be increased at the next IPL of z/OS.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages