M204.2102

From m204wiki
Jump to navigation Jump to search

M204.2102  CPTIME cannot be reset from zero

If Model 204 was initialized with the CPTIME parameter set to zero (the default value), it cannot later be reset to a non-zero value to initiate automatic checkpointing. In other words, automatic checkpointing can be activated only during Model 204 system initialization.

System manager response: Modify the CCAIN parameter stream to achieve the desired result for subsequent Model 204 runs

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter

Back to list of messages