M204.2121
Jump to navigation
Jump to search
M204.2121 Repeating AT-MOST-ONE field prohibited
The Load Repeating Field (LDRF) statement in Fastload (FLOD or FILELOAD) is checked at compile time to ensure that its execution will not violate the AT-MOST-ONE Field-Level Constraint. The message above is received when a user attempts to load multiple AT-MOST-ONE fields using the LDRF statement. Fastload is not executed due to error(s) in compilation.
Response: Remove the LDRF statement from the Fastload, or use LDRF on a field that is not defined with the AT-MOST-ONE Field-Level Constraint. Rerun the Fastload after correction.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |