M204.2489
Jump to navigation
Jump to search
M204.2489 IODEV parameter expected
Model 204 finished processing the User 0 parameter line, and it expected to find an IODEV parameter on the next line in the CCAIN input stream, but did not find one.
System manager response: Make sure that an IODEV parameter is specified on the first line for User 1. Check to make sure that the CCAIN stream does not contain any other errors that could cause Model 204 to process User 1's parameters prematurely, for example, missed continuation in User 0's parameter line.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |