M204.2830

From m204wiki
Jump to navigation Jump to search

M204.2830  Unable to allocate SDASDENQ work area - more entries exist

The SDASDENQ work area is allocated as part of ENQCTL command processing and as part of shared DASD enqueue processing. If there is insufficient storage (6K) available to allocate this work area, the ENQCTL command fails.

Response: Notify the system manager that the amount of virtual storage available to Model 204 needs to be increased.

System manager response: Increase the amount of virtual storage available to Model 204 using the REGION parameter on the job card (z/OS), DEFINE STOR (CMS), or the partition size (z/VSE).

Message attributes:

RETCODEO=4Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITMSWrites the message with line type MS to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter