MSIR.0198 Insufficient CCATEMP for (porttype) tables
(Redirected from MSIR.0198)
This message indicates that there were insufficient free CCATEMP pages to build new in-core/in-CCATEMP Janus Specialty Data Store tables. The porttype is SDS, OAS, or OMNI depending on what was entered on the JANUS DEFINE command for the port. Increase the amount of CCATEMP available to the Online or reduce the CCATEMP utilization in the Online.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |