MSIR.0550 SirSafe rules do not allow current security environment ((interface) (group))
Jump to navigation
Jump to search
This message indicates that the current security environment does not match any of the interfaces in the just or last issued AUTHCTL A
or AUTHCTL C
command. If an AUTHCTL A
or AUTHCTL C
command was just issued, the command is rejected.
If this message occurs while trying to bring up an Online, the Online will not initialize completely. The latter case is likely to be caused by:
- An Online running with a load module without the appropriate security module linked in.
- Some other security interface configuration problem.
Correct the security configuration or contact Technical Support if unable to determine the cause of the problem.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=0 | Sets batch (single user) return code |
CLASS=I | Information class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter |
AUDITMS | Writes the message with line type MS to the audit trail |
NOCOUNT | Does not increment the error count (ERCNT) parameter |