MSIR.0833 Can't set Model 6 -- (reason)
(Redirected from MSIR.0833)
A RESET MODEL 6 command could not be executed for the indicated reason. The most likely reason for this error is an insufficiently large LOUTPB, which can be corrected by increasing LOUTPB or setting a smaller screen size on the 3270 emulator that received this error.
Another likely cause of this error is use of an "old" 3270 emulator that does not support the Write Structured Field Query operation required to support the MODEL 6 capability. For such emulators, the correct model must be set "manually".
A wide variety of less common errors are also possible. If the reason indicated for such an error is not clear, contact Technical Support.
Message attributes:
RETCODEO=0 | Sets online return code |
---|---|
RETCODEB=4 | Sets batch (single user) return code |
CLASS=E | Error class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter |
AUDITER | Writes the message with line type ER to the audit trail |
COUNT | Increments the error count (ERCNT) parameter |
ECHO | Displays the line that caused the error |