MSIR.0833 Can't set Model 6 -- (reason): Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
(Automatically generated page update)
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
A <tt>RESET MODEL 6</tt> command could not be executed for the indicated reason. The most likely reasons for this error are an insufficiently large LOUTPB which can be corrected by increasing LOUTPB or setting a smaller screen size on the 3270 emulator that received this error. Another likely cause of this error is use of an "old" 3270 emulator that does not support the Write Structured Field Query operation required to support the MODEL 6 capability. For such emulators, the correct model must be set "manually". A wide variety of less common errors are also possible. If the reason indicated for such an error is not clear, contact [[Contacting Rocket Software Technical Support|Technical Support]].
A <var>RESET MODEL 6</var> command could not be executed for the indicated reason. The most likely reason for this error is an insufficiently large <var>[[LOUTPB parameter|LOUTPB]]</var>, which can be corrected by increasing <var>LOUTPB</var> or setting a smaller screen size on the 3270 emulator that received this error.  


[[Category:Sirius Mods messages]]
Another likely cause of this error is use of an "old" 3270 emulator that does not support the Write Structured Field Query operation required to support the MODEL 6 capability. For such emulators, the correct model must be set "manually".
 
A wide variety of less common errors are also possible. If the reason indicated for such an error is not clear, contact [[Contacting Rocket Software Technical Support|Technical Support]].
 
{{Template:MSIR.0833 footer}}
[[Category:MSIR.0800 - MSIR.0999]]

Latest revision as of 23:35, 3 March 2017

A RESET MODEL 6 command could not be executed for the indicated reason. The most likely reason for this error is an insufficiently large LOUTPB, which can be corrected by increasing LOUTPB or setting a smaller screen size on the 3270 emulator that received this error.

Another likely cause of this error is use of an "old" 3270 emulator that does not support the Write Structured Field Query operation required to support the MODEL 6 capability. For such emulators, the correct model must be set "manually".

A wide variety of less common errors are also possible. If the reason indicated for such an error is not clear, contact Technical Support.


Message attributes:

RETCODEO=0Sets online return code
RETCODEB=4Sets batch (single user) return code
CLASS=EError class; the message can be suppressed with the X'04' bit setting of the MSGCTL parameter
AUDITERWrites the message with line type ER to the audit trail
COUNTIncrements the error count (ERCNT) parameter
ECHODisplays the line that caused the error

Back to list of messages