NOTERM and NOTHREAD parameters
Jump to navigation
Jump to search
Summary
- Default value
- 0
- Parameter type
- User
- Where set
- On user's parameter line
- Related products
- All
- Introduced
- Model 204 V2.1 or earlier
Description
The number of terminals defined by the current group of user parameter lines
NOTERM or NOTHREAD (which are aliases of each other) must be set on the first user parameter line in a group. One terminal is defined by each user parameter line, and the value of the IODEV parameter must be the same on each parameter line.
The NOTERM and NOTHREAD parameters apply to the following device types:
IODEV | Access method/device type |
---|---|
7 | SNA Communications Server 3270 (z/OS and z/VM) |
11 | Remote User Language thread (full screen) |
19 | VTAM (Horizon for Connect:) |
27 | VTAM (Horizon) |
29 | Remote User Language thread (line-at-a-time) |
37 | SNA Communications Server 3767 and NTO (z/OS) Note: The IODEV=37 setting is no longer supported as of Model 204 version 7.6. |
39 | IUCV User Language thread (line-at-a-time) |
41 | IUCV User Language thread (full screen) |
43 | IUCV Host Language Interface thread |