SAMPLE command: Difference between revisions
No edit summary |
m (minor cleanup) |
||
Line 1: | Line 1: | ||
<p class="note"><b>Note:</b> This is a <var class="product">[[Sirius Mods]]</var>-only command prior to Version 7.5 of <var class="product">[[Model 204]]</var>.</p> | <p class="note"><b>Note:</b> This is a <var class="product">[[Sirius Mods]]</var>-only command prior to Version 7.5 of <var class="product">[[Model 204]]</var>.</p> | ||
This command either places [[SirTune]] sampling back into automatic mode (SAMPLE AUTO), | This command either places [[SirTune]] sampling back into automatic mode (<code>SAMPLE AUTO</code>), | ||
where sampling is controlled by INCLUDE/EXCLUDE statements in SIRTUNEI, or it | where sampling is controlled by INCLUDE/EXCLUDE statements in SIRTUNEI, or it | ||
initiates (SAMPLE ON) or terminates (SAMPLE OFF) collection of sample data. | initiates (<code>SAMPLE ON</code>) or terminates (<code>SAMPLE OFF</code>) collection of sample data. | ||
This command has no effect on the collection of compilation data: Compilation | This command has no effect on the collection of compilation data: Compilation | ||
data is collected regardless of the sampling state. | data is collected regardless of the sampling state. | ||
Line 9: | Line 9: | ||
For example, to immediately start collecting data, the following command | For example, to immediately start collecting data, the following command | ||
should be issued: | should be issued: | ||
< | <p class="code">SAMPLE ON | ||
</p> | |||
</ | |||
To immediately stop collecting data, issue: | To immediately stop collecting data, issue: | ||
< | <p class="code">SAMPLE OFF | ||
</p> | |||
</ | |||
After a SAMPLE ON or SAMPLE OFF command is issued, | After a <code>SAMPLE ON</code> or <code>SAMPLE OFF</code> command is issued, <var class="product">SirTune</var> is in "manual" sampling mode. | ||
is in | |||
This command is not available if the RESTART utility is responding to | This command is not available if the RESTART utility is responding to |
Latest revision as of 20:40, 11 November 2014
Note: This is a Sirius Mods-only command prior to Version 7.5 of Model 204.
This command either places SirTune sampling back into automatic mode (SAMPLE AUTO
),
where sampling is controlled by INCLUDE/EXCLUDE statements in SIRTUNEI, or it
initiates (SAMPLE ON
) or terminates (SAMPLE OFF
) collection of sample data.
This command has no effect on the collection of compilation data: Compilation
data is collected regardless of the sampling state.
For example, to immediately start collecting data, the following command should be issued:
SAMPLE ON
To immediately stop collecting data, issue:
SAMPLE OFF
After a SAMPLE ON
or SAMPLE OFF
command is issued, SirTune is in "manual" sampling mode.
This command is not available if the RESTART utility is responding to operator commands.