MODEL parameter: Difference between revisions
m (minor formatting) |
|||
(4 intermediate revisions by 4 users not shown) | |||
Line 24: | Line 24: | ||
For terminals communicating through SNA Communications Server, CICS, IUCV, or TSO, <var class="product">Model 204</var> automatically sets <var>MODEL</var> to the appropriate value when the session begins, provided that the size of the output page buffer (<var>[[LOUTPB parameter|LOUTPB]]</var>) is large enough to hold the new screen size. </p> | For terminals communicating through SNA Communications Server, CICS, IUCV, or TSO, <var class="product">Model 204</var> automatically sets <var>MODEL</var> to the appropriate value when the session begins, provided that the size of the output page buffer (<var>[[LOUTPB parameter|LOUTPB]]</var>) is large enough to hold the new screen size. </p> | ||
<p> | <p> | ||
If you set the <var>[[FSTRMOPT parameter|FSTRMOPT]]</var> parameter to 2, the <var>MODEL</var> parameter is not reset dynamically. When the value of <var>MODEL</var> is reset from 2 (the default), the values of the <var>[[OUTLPP parameter|OUTLPP]]</var>, <var>[[OUTMRL parameter|OUTMRL]]</var>, <var>[[INMRL parameter|INMRL]]</var>, <var>[[OUTCCC parameter|OUTCCC]]</var>, and <var>[[INCCC parameter| | If you set the <var>[[FSTRMOPT parameter|FSTRMOPT]]</var> parameter to 2, the <var>MODEL</var> parameter is not reset dynamically. When the value of <var>MODEL</var> is reset from 2 (the default), the values of the <var>[[OUTLPP parameter|OUTLPP]]</var>, <var>[[OUTMRL parameter|OUTMRL]]</var>, <var>[[INMRL parameter|INMRL]]</var>, <var>[[OUTCCC parameter|OUTCCC]]</var>, and <var>[[INCCC parameter|INCCC]]</var> parameters are adjusted accordingly, as shown in the following example.</p> | ||
<p> | <p> | ||
The screen-size parameter settings for IBM 3270 terminals are shown in the table below. <var>OUTLPP</var>, <var>OUTMRL</var>, <var> | The screen-size parameter settings for IBM 3270 terminals are shown in the table below. <var>OUTLPP</var>, <var>OUTMRL</var>, <var>INMRL</var>, <var>OUTCCC</var>, <var>[[INCCC_parameter|INCCC]]</var> are all reset automatically as part of the <code>RESET MODEL</code> command.</p> | ||
<table> | <table> | ||
<caption>Screen-size parameter settings </caption> | <caption>Screen-size parameter settings </caption> | ||
<tr class="head"><th> MODEL</th><th>MINIMUM LOUTPB</th><th> OUTLPP</th><th> OUTMRL</th><th> INMRL</th><th> OUTCCC</th><th> INCCC</th><th> TYPE</th></tr> | <tr class="head"><th> MODEL</th><th>MINIMUM LOUTPB</th><th> OUTLPP</th><th> OUTMRL</th><th> INMRL</th><th> OUTCCC</th><th> INCCC</th><th> TYPE</th></tr> | ||
<tr><th align="right"><var> 1</var></th><td>1170</td><td>11</td><td> 80</td><td> 78</td><td> 80</td><td> 78</td><td>IBM 327x Model 1</td></tr> | <tr><th align="right"><var> 1</var></th> | ||
<td>1170</td><td>11</td><td> 80</td> | |||
<td> 78</td><td> 80</td><td> 78</td> | |||
<td>IBM 327x Model 1</td></tr> | |||
<tr><th align="right"><var> 2</var></th><td>2130</td><td>23</td><td> 80</td><td> 78</td><td> 80</td><td> 78</td><td>IBM 327x Model 2</td></tr> | <tr><th align="right"><var> 2</var></th> | ||
<td>2130</td><td>23</td><td> 80</td> | |||
<td> 78</td><td> 80</td><td> 78</td> | |||
<td>IBM 327x Model 2</td></tr> | |||
<tr><th align="right"><var> 3</var></th><td>2770</td><td>31</td><td> 80</td><td> 78</td><td> 80</td><td> 78</td><td>IBM 327x Model 3</td></tr> | <tr><th align="right"><var> 3</var></th> | ||
<td>2770</td><td>31</td><td> 80</td> | |||
<td> 78</td><td> 80</td><td> 78</td> | |||
<td>IBM 327x Model 3</td></tr> | |||
<tr><th align="right"><var> 4</var></th><td>3650</td><td>42</td><td> 80</td><td> 78</td><td> 80</td><td> 78</td><td>IBM 327x Model 4</td></tr> | <tr><th align="right"><var> 4</var></th> | ||
<td>3650</td><td>42</td><td> 80</td> | |||
<td> 78</td><td> 80</td><td> 78</td> | |||
<td>IBM 327x Model 4</td></tr> | |||
<tr><th align="right"><var> 5</var></th><td>3774</td><td>26</td><td>132</td><td>130</td><td>132</td><td>130</td><td>IBM 327x Model 5</td></tr> | <tr><th align="right"><var> 5</var></th> | ||
<td>3774</td><td>26</td><td>132</td> | |||
<td>130</td><td>132</td><td>130</td> | |||
<td>IBM 327x Model 5</td></tr> | |||
<tr><th align="right"><var> 6</var></th><td>custom</td><td>custom</td><td>custom</td><td>custom</td><td>custom</td><td>custom</td><td>Custom | <tr><th align="right"><var> 6</var></th> | ||
<td>custom</td><td>custom</td><td>custom</td> | |||
<td>custom</td><td>custom</td><td>custom</td> | |||
<td>Custom TN3270 setting — see [[Terminal MODEL 6 support]]</td></tr> | |||
</table> | </table> | ||
< | <blockquote class="note"><b>Notes:</b> | ||
<ul> | |||
<li>The 3278 Model 2A and the 3279 Model 2C system consoles are not supported in full screen mode.</li> | |||
<li>When <var>MODEL</var> is reset to 6, the value (as displayed by <var>VIEW</var> and as returned by <var>$View</var>) is: | |||
<p class="output">6 <i>nRows</i>*<i>nCols</i> | |||
</p> | |||
The values are determined by the TN3270 client setup. | |||
<p> | <p> | ||
When <var>MODEL</var> is reset, any existing backpages can no longer be displayed.</ | As indicated in the above table, the values of the other parameters depend on <i>nRows</i> and <i>nCols</i>. The values of <var>OUTMRL</var> and <var>OUTCC</var> are each equal to <i>nCols</i>. | ||
</p></li> | |||
<li>When <var>MODEL</var> is reset, any existing backpages can no longer be displayed.</li> | |||
</ul> | |||
</blockquote> | |||
[[Category:User parameters]] | [[Category:User parameters]] | ||
[[Category:Parameters]] | [[Category:Parameters]] |
Latest revision as of 17:57, 15 September 2017
Terminal model
Summary
- Default value
- 2
- Parameter type
- User
- Where set
- On user's parameter line
- Related products
- All
- Introduced
- Model 204 V6.1 or earlier
Description
The alternate screen sizes corresponding to the different models within the IBM 3270 family of terminals
These sizes are available at command level and during output from SOUL statements. For all values except MODEL=5
, they also are available for SOUL screens and menus and the Full Screen Editor.
For MODEL=5
, SOUL screens and menus use the full height (26 available lines), but only up to 80 columns of width. In addition, if MODEL=5
, the Full Screen Editor uses the size corresponding to MODEL=2
.
For terminals communicating through SNA Communications Server, CICS, IUCV, or TSO, Model 204 automatically sets MODEL to the appropriate value when the session begins, provided that the size of the output page buffer (LOUTPB) is large enough to hold the new screen size.
If you set the FSTRMOPT parameter to 2, the MODEL parameter is not reset dynamically. When the value of MODEL is reset from 2 (the default), the values of the OUTLPP, OUTMRL, INMRL, OUTCCC, and INCCC parameters are adjusted accordingly, as shown in the following example.
The screen-size parameter settings for IBM 3270 terminals are shown in the table below. OUTLPP, OUTMRL, INMRL, OUTCCC, INCCC are all reset automatically as part of the RESET MODEL
command.
MODEL | MINIMUM LOUTPB | OUTLPP | OUTMRL | INMRL | OUTCCC | INCCC | TYPE |
---|---|---|---|---|---|---|---|
1 | 1170 | 11 | 80 | 78 | 80 | 78 | IBM 327x Model 1 |
2 | 2130 | 23 | 80 | 78 | 80 | 78 | IBM 327x Model 2 |
3 | 2770 | 31 | 80 | 78 | 80 | 78 | IBM 327x Model 3 |
4 | 3650 | 42 | 80 | 78 | 80 | 78 | IBM 327x Model 4 |
5 | 3774 | 26 | 132 | 130 | 132 | 130 | IBM 327x Model 5 |
6 | custom | custom | custom | custom | custom | custom | Custom TN3270 setting — see Terminal MODEL 6 support |
Notes:
- The 3278 Model 2A and the 3279 Model 2C system consoles are not supported in full screen mode.
- When MODEL is reset to 6, the value (as displayed by VIEW and as returned by $View) is:
6 nRows*nCols
The values are determined by the TN3270 client setup.
As indicated in the above table, the values of the other parameters depend on nRows and nCols. The values of OUTMRL and OUTCC are each equal to nCols.
- When MODEL is reset, any existing backpages can no longer be displayed.