Max input record length
Summary
- Default value
- 80
- Parameter type
- User
- Where set
- On user's parameter line; reset by any user
- Related products
- All
- Introduced
- Model 204 V2.1 or earlier
Description
The maximum input line length
For most devices, Model 204 overrides the initial setting or the default value of INMRL and uses the INMRL value set by the Model 204 MODEL parameter value. If MODEL is reset to accommodate an alternative screen size within the 3270 terminal family, the value of INMRL changes accordingly.
INMRL is meaningful when an I/O device is initialized. Therefore, a RESET INMRL
command has no effect.
If INMRL is being reset for User 0 input, it must be reset with the parameters passed by the operating system when Model 204 is invoked.
INMRL is typically set on the user's parameter line. It can be specified only for the following devices:
IODEV | Access method/device type |
---|---|
3 | BSAM |
7 | SNA Communications Server 3270 |
11 | Remote User Language thread (full screen) |
19 | VTAM or TCP/IP (Horizon SQL thread) |
29 | Remote User Language thread (line-at-a-time) |
37 | SNA Communications Server 3767 and NTO Note: The IODEV=37 setting is no longer supported as of Model 204 version 7.7. |
39 | IUCV User Language thread (line-at-a-time) |
45 | CMS (line-at-a-time) console |
49 | VTAM or TCP/IP (Horizon RCL thread) |