M204.0434

From m204wiki
Jump to navigation Jump to search

M204.0434  buffType set to number

The NJBUFF or the NLBUFF parameter was reset to an invalid value.

NJBUFF specifies the number of journal buffers allocated by Model 204 during initialization. Its value must be equal to either of these:

  • One (1)
  • Value of: NSERVS parameter, plus NSUBTKS parameter, plus 1

For NLBUFF parameter sizing information, see NLBUFF parameter.

Response: Notify the system manager.

System manager response: Reset the NJBUFF parameter to a valid value, and rerun Model 204.

Message attributes:

RETCODEO=0Sets online return code
RETCODEB=0Sets batch (single user) return code
CLASS=IInformation class; the message can be suppressed with the X'02' bit setting of the MSGCTL parameter
AUDITADWrites the message with line type AD to the audit trail
NOCOUNTDoes not increment the error count (ERCNT) parameter