SirMon main menu: Difference between revisions
m (mention RKWeb equivalents) |
No edit summary |
||
(2 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
The <var class="product">SirMon</var> main menu is the primary entry point in the <var class="product">SirMon</var> | The <var class="product">SirMon</var> main menu is the primary entry point in the <var class="product">SirMon</var> TN3270 interface. It is accessed in any of the following ways: | ||
<ul> | <ul> | ||
<li>Entering the subsystem name <code>SIRMON</code> at <var class="product">Model 204</var> command level.</li> | <li>Entering the subsystem name <code>SIRMON</code> at <var class="product">Model 204</var> command level.</li> | ||
Line 11: | Line 11: | ||
</ul> | </ul> | ||
In RKWeb, selecting the Monitor > Performance option displays an equivalent menu. | In [[RKWeb]], selecting the <code>Monitor > Performance</code> option displays an equivalent menu. | ||
<p class="caption" style="width:475px">SirMon main menu</p> | <p class="caption" style="width:475px">SirMon main menu</p> | ||
Line 46: | Line 46: | ||
</table> | </table> | ||
Each of the sub-menus | Each of the SirMon sub-menus allows up to 32 views of information | ||
within the statistics category. | within the statistics category. | ||
A small number of views come pre-formatted with <var class="product">SirMon</var> | A small number of views come pre-formatted with <var class="product">SirMon</var>. | ||
==Custom views== | ==Custom views== | ||
Line 65: | Line 58: | ||
view is unique to that user. | view is unique to that user. | ||
In RKWeb, you access the custom-view definition page by selecting the Monitor > Performance > Custom option. | In RKWeb, you access the custom-view definition page by selecting the <code>Monitor > Performance > Custom</code> option. | ||
==See also== | ==See also== |
Latest revision as of 23:22, 22 June 2017
The SirMon main menu is the primary entry point in the SirMon TN3270 interface. It is accessed in any of the following ways:
- Entering the subsystem name
SIRMON
at Model 204 command level. - Selecting the
Monitor
option from the RKTools main menu. - Typing
=
in the command window of any SirMon screen. - Typing
Mon
in any RKTools screen.
In RKWeb, selecting the Monitor > Performance
option displays an equivalent menu.
The SirMon main menu options are described below:
1. System Overview Screen | Presents the major items of interest for measuring and determining the current condition of the active, online Model 204 region. This single panel, described further in SirMon System Overview screen, presents each statistic as a rate per second and per screen (where appropriate), and as a total.
Threshold setting (SirMon threshold setting) and background task definition and initialization (SirMon background monitor) are accessed from this screen. |
---|---|
2. System Monitor | Presents a sub-menu of monitoring screens (see SirMon System Monitor menu) that are specific to the system's overall condition and performance. |
3. User Monitor | Presents a sub-menu of monitoring screens (see SirMon User Monitor menu) that show specific views of all users in the system. |
4. File Monitor | Presents a sub-menu of monitoring screens (see SirMon File Monitor menu) that show specific views of all open files in the system. |
5. Subsystem Monitor | Presents a sub-menu of monitoring screens (see SirMon Subsystem Monitor menu) that show specific views of subsystems defined to the system. The second option on this submenu provides information for both active and inactive subsystems. This includes a list of defined subsystems, their running status, number of active users, procedure prefixes and access type.
Subsystems may be started and stopped from this screen. |
6. MP Task Monitor | Presents a sub-menu of monitoring screens (see SirMon Task Monitor menu) that show specific views of all tasks in the system. If the MP/204 feature is not installed, the task monitor screens only display information for the maintask (task 0). |
7. Janus Port Monitor | Presents a sub-menu of monitoring screens that show specific views of activity at Janus ports defined in the Online. For further details, see the JANUS STATUS command. |
Each of the SirMon sub-menus allows up to 32 views of information within the statistics category. A small number of views come pre-formatted with SirMon.
Custom views
Users may define and save additional custom views, as described in SirMon custom screens.
In addition to system-wide custom views that appear on the menus for all
users, SirMon allows individual users to save a single "adhoc" view for each menu.
User adhocs are accessed as menu option A
on each menu (so a user's
File adhoc is accessed as SIRMON 4.A
), and each user's
view is unique to that user.
In RKWeb, you access the custom-view definition page by selecting the Monitor > Performance > Custom
option.
See also
- SirMon
- SirMon application structure
- SirMon main menu
- SirMon System Overview screen
- SirMon threshold setting
- SirMon background monitor
- SirMon System Monitor menu
- SirMon User Monitor menu
- SirMon File Monitor menu
- SirMon Subsystem Monitor menu
- SirMon Task Monitor menu
- SirMon Janus Monitor menu
- SirMon custom screens
- SirMon critical-file-resource monitoring
- SirMon user-initiated capturing of statistics
- System statistics displayed in SirMon
- User statistics displayed in SirMon
- File statistics displayed in SirMon
- Subsystem statistics displayed in SirMon
- Task statistics displayed in SirMon
- Critical File Resource statistics displayed in SirMon
- SirMon date processing