SCRNSTBL parameter: Difference between revisions

From m204wiki
Jump to navigation Jump to search
(Automatically generated page update)
(Automatically generated page update)
Line 1: Line 1:
{{Template:SCRNSTBL parameter subtitle}}
==Summary==
==Summary==
<dl>
<dl>

Revision as of 16:43, 27 August 2013

STBL size for Screen objects

Summary

Default value
6144
Parameter type
User
Where set
System manager resettable
Related products
All
Introduced
Sirius Mods 7.1

Description

This is a numeric parameter (with valid values 0 or greater) that indicates the maximum amount of STBL space available to Janus SOAP Screen objects. Screen objects use STBL space and not FSCB space, and any instance of a Screen object must allocate the maximum allowable STBL space, even if some of this space may not be used by a particular application.

An application that exceeds its screen STBL allocation is cancelled, usually with a message like:

MSIR.0750: Class Screen, function AddField: no more space for screen field data ...

Some Sirius ULSPF products, like SirScan and SirPro, also make use of screen objects. The SCRNSTBL default value is sufficient for those products for Model 2 terminals. However, the default SCRNSTBL might not be sufficient for other terminal models, especially Model 4 or Model 6 terminals.

Note that the SCRNSTBL parameter affects the space allocated for Screen objects at compilation time. As such, increasing SCRNSTBL will not increase the amount of space available to pre-compiled requests unless those requests are re-compiled after resetting SCRNSTBL.