IODEV parameter: Difference between revisions
Jump to navigation
Jump to search
Line 31: | Line 31: | ||
<tr><th align="right"><var>41</var></th><td>IUCV User Language thread (full screen)</td></tr> | <tr><th align="right"><var>41</var></th><td>IUCV User Language thread (full screen)</td></tr> | ||
<tr><th align="right"><var>43</var></th><td>IUCV Host Language Interface thread</td></tr> | <tr><th align="right"><var>43</var></th><td>IUCV Host Language Interface thread</td></tr> | ||
<tr><th align="right"><var>45</var></th><td>CMS line-at-a-time console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line.</td></tr> | <tr><th align="right"><var>45</var></th><td>CMS line-at-a-time console. This z/VM device setting is an <var>[[ALTIODEV_parameter|ALTIODEV]]</var> value; is cannot be specified on the user's parameter line.</td></tr> | ||
<tr><th align="right"><var>47</var></th><td>CMS full screen console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. </td></tr> | <tr><th align="right"><var>47</var></th><td>CMS full screen console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. </td></tr> | ||
<tr><th align="right"><var>49</var></th><td>VTAM or TCP/IP Horizon Remote Command Line (RCL) thread.</td></tr> | <tr><th align="right"><var>49</var></th><td>VTAM or TCP/IP Horizon Remote Command Line (RCL) thread.</td></tr> |
Revision as of 15:04, 28 October 2014
Type of I/O device
Summary
- Default value
- 1
- Parameter type
- User
- Where set
- On user's parameter line
- Related products
- All
- Introduced
- Model 204 V2.1 or earlier
Description
The input/output device type
Valid settings of IODEV are:
IODEV | Access method/device type |
---|---|
1 | CCAIN/CCAPRINT (User 0 only) |
3 | BSAM |
7 | SNA Communications Server 3270 |
11 | Remote User Language thread (full screen) |
19 | VTAM or TCP/IP (Horizon SQL thread) |
23 | Host Language IFAM thread |
27 | VTAM (Horizon thread) |
29 | Remote User Language thread (line-at-a-time) |
37 | SNA Communications Server 3767 and NTO (z/OS) |
39 | IUCV User Language thread (line-at-a-time) |
41 | IUCV User Language thread (full screen) |
43 | IUCV Host Language Interface thread |
45 | CMS line-at-a-time console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. |
47 | CMS full screen console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. |
49 | VTAM or TCP/IP Horizon Remote Command Line (RCL) thread. |
51 | SNA Communications Server (Parallel Query Option/204 thread) |
Note: In addition to the above table of valid settings of the IODEV parameter, the value of IODEV on some Model 204 threads can be set as a result of other parameters:
Parameter Recommended Meaning SDAEMDEV 15 IODEV number for Sdaemons TNDEV 21 IODEV number for TNSERV threads