IODEV parameter: Difference between revisions

From m204wiki
Jump to navigation Jump to search
Line 27: Line 27:
<tr><th align="right"><var>27</var></th><td>VTAM (Horizon thread)</td></tr>
<tr><th align="right"><var>27</var></th><td>VTAM (Horizon thread)</td></tr>
<tr><th align="right"><var>29</var></th><td>Remote User Language thread (line-at-a-time)</td></tr>
<tr><th align="right"><var>29</var></th><td>Remote User Language thread (line-at-a-time)</td></tr>
<tr><th align="right"><var>37</var></th><td>SNA Communications Server 3767 and NTO (z/OS)</td></tr>
<tr><th align="right"><var>37</var></th><td>SNA Communications Server 3767 and NTO (z/OS)
<p class="note"><b>Note:</b> Value 37 is no longer supported as of Model 204 version 7.7.</p></td></tr>
<tr><th align="right"><var>39</var></th><td>IUCV User Language thread (line-at-a-time)</td></tr>
<tr><th align="right"><var>39</var></th><td>IUCV User Language thread (line-at-a-time)</td></tr>
<tr><th align="right"><var>41</var></th><td>IUCV User Language thread (full screen)</td></tr>
<tr><th align="right"><var>41</var></th><td>IUCV User Language thread (full screen)</td></tr>

Revision as of 16:53, 8 August 2016

Type of I/O device

Summary

Default value
1
Parameter type
User
Where set
On user's parameter line
Related products
All
Introduced
Model 204 V2.1 or earlier

Description

The input/output device type

Valid settings of IODEV are:

IODEVAccess method/device type
1CCAIN/CCAPRINT (User 0 only)
3BSAM
7SNA Communications Server 3270
11Remote User Language thread (full screen)
19VTAM or TCP/IP (Horizon SQL thread)
23Host Language IFAM thread
27VTAM (Horizon thread)
29Remote User Language thread (line-at-a-time)
37SNA Communications Server 3767 and NTO (z/OS)

Note: Value 37 is no longer supported as of Model 204 version 7.7.

39IUCV User Language thread (line-at-a-time)
41IUCV User Language thread (full screen)
43IUCV Host Language Interface thread
45CMS line-at-a-time console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line.
47CMS full screen console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line.
49VTAM or TCP/IP Horizon Remote Command Line (RCL) thread.
51SNA Communications Server (Parallel Query Option/204 thread)

Note: In addition to the above table of valid settings of the IODEV parameter, the value of IODEV on some Model 204 threads can be set as a result of other parameters:

ParameterRecommendedMeaning
SDAEMDEV15IODEV number for Sdaemons
TNDEV21IODEV number for TNSERV threads