Release notes for Model 204 version 7.5: Difference between revisions
Line 553: | Line 553: | ||
<p><b>Response:</b> Check that NUSERS matches the total of the listed IODEVs, plus one extra for USER 0. Check also the NOTERM/DUPTERM parameter for the specified IODEV card.</p> | <p><b>Response:</b> Check that NUSERS matches the total of the listed IODEVs, plus one extra for USER 0. Check also the NOTERM/DUPTERM parameter for the specified IODEV card.</p> | ||
<p><b>Return Codes:</b> E 80 80 ER</p> | <p><b>Return Codes:</b> E 80 80 ER</p> | ||
----'''M204.2826:''' | ---- | ||
'''M204.2719: | |||
<br>OPEN %C FAILED. UPDATE STATEMENTS ALREADY COMPILED, READ ONLY PRIVILEGES INSUFFICIENT | |||
<p><b>Explanation:</b> The OPEN or OPENC User Language statement was issued from a request to reopen a file with read-only privileges. However, that request had already been compiled with update statements against the file.</p> | |||
<p><b>Response:</b> In a User Language request, you cannot use the User Language OPEN or OPENC statement to reopen a file with read-only privileges, if that request contains updates statements against the same file.</p> | |||
<p><b>Descriptor code:</b> C 0 4 CANCEL</p> | |||
---- | |||
'''M204.2739: | |||
<br> | |||
PARAMETER parm CANNOT BE RESET ON USER 0’S PARAMETER LINE: VALUE IGNORED | |||
<p><b>Explanation:</b> You reset parameter <i>parm </i>on the User 0 parameter line, but the parameter cannot be set there. The value is ignored, the default value for this parameter remains in effect.</p> | |||
<p><b>Response:</b> Remove <i>parm</i> from the User 0 parameters, since it will not change the value of the parameter.</p> | |||
<p><b>Descriptor code:</b> E 0 4 AD</p> | |||
---- | |||
'''M204.2746: | |||
<br> | |||
XSIZE*XRECPPG MAY NOT BE 1 NOR EXCEED 536870911 | |||
<p><b>Explanation:</b> The product of XSIZE and XRECPPG must not exceed 16777216 times 32 minus one, or 536870911. This specifies the maximum number of extension records allowed in a single Model 204 file when using Table X. Also, setting both XRECPPG and XSIZE to 1 is invalid.</p> | |||
The CREATE command is rejected. | |||
<p><b>Response:</b> Retry the command specifying values for XSIZE and XRECPPG whose product does not exceed the 526870911 limit. Refer to the <var class="book">Rocket Model 204 File Manager’s Guide </var>for more information on file sizes.</p> | |||
<p><b>Descriptor code:</b> C 0 4</p> | |||
---- | |||
'''M204.2826:''' | |||
<br> | <br> | ||
'''%F VERSION IS PRE 6.3. COMPACTION NOT ALLOWED''' | '''%F VERSION IS PRE 6.3. COMPACTION NOT ALLOWED''' | ||
Line 561: | Line 583: | ||
<br>'''Return Codes:''' C 0 4 AUDITER | <br>'''Return Codes:''' C 0 4 AUDITER | ||
---- | |||
'''M204.2831: | |||
<br> | |||
UPDATES TO DTS FILES NOT SUPPORTED IN THIS ENVIRONMENT | |||
<p><b>Explanation:</b> DTS files cannot be updated in IFAM, SQL, or PQO environments.</p> | |||
<p><b>Response:</b> Do not attempt to update DTS file.</p> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
'''M204.2833: | |||
<br> | |||
FIELDS CANNOT BE DEFINED IN A FILE WITH ATRPG*ASTRPPG>4000 | |||
<p>Return Codes: C 0 4</p> | |||
---- | ---- | ||
'''M204.2836:''' | '''M204.2836:''' | ||
Line 571: | Line 605: | ||
<br>'''System Manager Response:''' The parameter has been reset. No response required. | <br>'''System Manager Response:''' The parameter has been reset. No response required. | ||
<br>'''Return Codes:''' I 0 0 AUDITMS | <br>'''Return Codes:''' I 0 0 AUDITMS | ||
---- | |||
<b>2838: %C ONLY VALID IN FILEORG X’100’ FILES</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2839: %C IS A %C, NOT A %C</b> | |||
<p><b>Return Codes:</b> C 0 4 ECHO</p> | |||
---- | |||
<b>2841: REMOTE FIELDGROUPS NOT SUPPORTED</b> | |||
<p><b>Return Codes:</b> C 0 4 ECHO</p> | |||
---- | |||
<b>2842: INVALID CONTEXT FOR FIELDGROUP</b> | |||
<p><b>Return Codes:</b> C 0 4 ECHO</p> | |||
---- | |||
<b>2843: MAXIMUM FIELDGROUP ID EXCEEDED IN RECORD %R IN %F</b> | |||
<p>Return Codes: C 0 4 CANCEL</p> | |||
---- | |||
<b>2844: MIX OF FIELDS AND FIELDGROUPS, NAME =</b> | |||
<p><b>Return Codes:</b> C 0 4 SUFFIX ECHO</p> | |||
---- | |||
<b>2845: INVALID FIELDGROUP CONTEXT FOR %C</b> | |||
<p><b>Explanation:</b> The $function was used outside of field group context.</p> | |||
<p><b>Descriptor code:</b>C 0 4 SUFFIX ECHO</p> | |||
---- | |||
<b>2846: INVALID FIELDGROUP CONTEXT FOR %C</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2847: FIELDGROUP CONTEXT LOST IN RECORD %R IN %F</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2848: INVALID FIELDGROUP ID: %C</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2849: REQUIRED KEYWORD %C MISSING</b> | |||
<p><b>Return Codes: </b>X 0 4 ECHO</p> | |||
---- | |||
<b>2850: %C VALUE MISSING</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2851: %C VALUE "%C" TOO BIG, MUST BE <%C BYTES</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2852: UPDATE TO MISSING FIELDGROUP OCCURRENCE IN RECORD %R IN %F</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2853: %C NOT ALLOWED FOR EXACTLY-ONE FIELD</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2854: ATTEMPT TO DO %C FOR EXACTLY-ONE FIELD: %C</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2855: FIELD DEPTH+LENGTH UNREPRESENTABLE IN RECORD %R IN %F</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2856: FIELDNAME VARIABLE %C: EXPECTED %C, GOT %C</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2857: %C FIELD NOT ALLOWED FOR %C FIELD</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2858: FIELDGROUP CONTEXT MISMATCH BETWEEN COUNTOCCURRENCES- OF FIELD AND COUNTED FIELD</b> | |||
<p><b>Return Codes: </b>C 0 4</p> | |||
---- | |||
<b>2859: NEW AUTOMATIC FIELD NOT ALLOWED FOR NON-EMPTY FILE</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2860: FIELD %C ALREADY HAS A COUNT-OCCURRENCES-OF FIELD</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2861: OCCURRENCE COUNTER %C OVERFLOWED</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2862: ATTEMPT TO UPDATE AUTOMATIC FIELD %C</b> | |||
<p><b>Return Codes:</b> C 0 4 SUFFIX ECHO</p> | |||
---- | |||
<b>2863: ATTEMPT TO DO %C FOR AUTOMATIC FIELD: %C</b> | |||
<p><b>Return Codes: </b>C 0 4 CANCEL</p> | |||
---- | |||
<b>2865:CANCELATTEMPT TO %C INVALID DATETIME VALUE: %C = %C' </b> | |||
<p><b>Return Codes: </b>C 0 4 CANCEL</p> | |||
---- | |||
<b>2866: FILE ALREADY HAS %C FIELD</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2867: FIELDGROUP %C ALREADY HAS %C FIELD</b> | |||
<p><b>Explanation:</b> If you try to define a second update tracker field of the same type for the same field group, you will invoke message 2867, where %C represents: | |||
<ul> | |||
<li>A CREATE-TIME</li> | |||
<li>A CREATE-TIMEUTC</li> | |||
<li>A CREATE-USER</li> | |||
<li>AN UPDATE-TIME</li> | |||
<li>AN UPDATE-TIMEUTC</li> | |||
<li>AN UPDATE-USER</li> | |||
</ul> | |||
</p> | |||
<p><b>Return Codes:</b> C O 4</p> | |||
---- | |||
<p><b>2868: MINLOBE MUST BE BETWEEN 0 AND %C'</b></p> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | ---- | ||
'''M204.2869:''' | '''M204.2869:''' | ||
Line 582: | Line 740: | ||
'''CHANGE REFUSED: MINLOBE > 0 FOR %F FIELD %C''' | '''CHANGE REFUSED: MINLOBE > 0 FOR %F FIELD %C''' | ||
<br>'''Return Codes:''' C 0 4 CANCEL AUDITER | <br>'''Return Codes:''' C 0 4 CANCEL AUDITER | ||
---- | |||
<b>2871: FIELDGROUP CONTEXT MISMATCH BETWEEN CONCATENATION-OF FIELD AND COMPONENT FIELD'</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2872: CONCATENATION VALUE TOO LONG FOR FIELD %C'</b> | |||
<p><b>Return Codes: </b>C 0 4 CANCEL</p> | |||
---- | |||
<b>2873: CONCATENATION FIELD %C COMPONENT FIELD %C CONTAINS SEPARATOR CHARACTER'</b> | |||
<p><b>Return Codes: </b>C 0 4 CANCEL</p> | |||
---- | |||
<b>2874: ATTEMPT TO %C A VALUE THAT'S %C: %C</b> | |||
<p><b>Return Codes: </b>C 0 4 CANCEL</p> | |||
---- | |||
<b>2875: CONCATENATION LIST INVALID: %C'</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2876: INVALID %C VALUE: %C'</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2877: WITH CLAUSE INVALID: %C'</b> | |||
<p><b>Return Codes: C 0 4 ECHO</b></p> | |||
---- | |||
<b> 2878: WITH CLAUSE INVALID: FIELD %C IN %F %C</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2879: REMOTE ID %C MODE %C'</b> | |||
<p><b>Return Codes: I 0 0 SAVE NOTERM OPR</b></p> | |||
---- | |||
<b>2880: MEMORY DATASETS CANNOT BE PART OF MULTI-DATASET FILE</b> | |||
<p><b>Return Codes: C 0 4</b></p> | |||
---- | |||
<b>2881: DATA CONVERSION ERROR</b> | |||
<p><b>Return Codes:</b> C 0 4 CANCEL</p> | |||
---- | |||
<b>2882: RECOVERY JOURNAL VERSION %X IS NOT SUPPORTED</b> | |||
<p><b>Return Codes:</b>E 0 4 OPR</p> | |||
---- | |||
<b>2884: [FIELD | FIELDGROUP] WAS PREVIOUSLY DEFINED AS A [FIELDGROUP | FIELD], NEW DEFINITION IGNORED</b> | |||
<p><b>Return Codes:</b> C 0 4</p> | |||
---- | |||
<b>2885: INVALID FIELDGROUP ID: fieldgroup</b> | |||
<b>Return Codes:</b> C 0 4 CANCEL | |||
---- | |||
<b>2886: FIELDGROUP ID %C ALREADY EXISTS IN RECORD %R IN %F'</b> | |||
<b>Return Codes:</b> C 0 4 | |||
---- | |||
<b>2903: FILEORG=X'100' IS NOT SUPPORTED DURING FLOD/FILELOAD</b> | |||
<b>Return Codes:</b> E 0 8 | |||
---- | ---- | ||
'''M204.2933:''' | '''M204.2933:''' |
Revision as of 19:35, 17 June 2013
These release notes list the enhancements and other changes contained in Model 204 version 7.5, which is still in development. Until the commercial release of the software, Rocket reserves the right to add to, remove, or change anything described herein.
Overview
These release notes contain installation and features information for the Rocket Model 204 version 7.5.0 release. Before beginning your installation, please read through this information about product installation and changes.
New in this release
This section summarizes the new features and enhancements for Model 204 version 7.5.0.
SOUL (User Language)
The significantly enhanced, object-oriented, version of User Language is now called SOUL. All existing User Language programs will continue to work under SOUL, so User Language can be considered to be a subset of SOUL, though the name User Language is now deprecated.
Feature | Operating System |
---|---|
Sirius object-oriented language extensions integration | z/VM, z/OS, z/VSE |
ECF statements can pass up to 60 parameters | z/VM, z/OS, z/VSE |
System Management
Feature | Operating System |
---|---|
Writing records to the SMF data set without an SVC installed | z/VM, z/OS, z/VSE |
Performance
Feature | Operating System |
---|---|
GTBL can be stored above the bar | z/VM, z/OS, z/VSE |
Operating system requirements
Requirements for Model 204 version 7.5.0 are still being determined.
Model 204 version 7.4.0 required the following operating system support:
- For IBM z/OS: Version 1 Release 7 is sufficient for all new functionality except for the following
features:
- Large (1 MB) page support requires Version 1 Release 9.
- Extended address volumes (EAV) requires Version 1 Release 12.
- For IBM z/VM: Version 5 Release 4.0 or later
- For IBM z/VSE:
- Version 5 Release 1 or
- Version 4 Release 3 or
- Version 4 Release 2.1 or
- Version 4 Release 2.0, with these program temporary fixes (PTFs) installed:
- UD53436
- UD53437
- UD53438
- UD53439
Hardware requirements
Requirements for Model 204 version 7.5.0 are still being determined.
Model 204 version 7.4.0 required the IBM z/890 or above processor, except for the following feature:
The large (1 MB) page support feature requires the IBM z10 or above processor.
Model 204 compatibility with operating systems
Content in this section is still to be determined.
Model 204 compatibility with Connect*
All supported versions of Connect* are compatible with Model 204 version 7.5.0. However, CLOB/BLOB support requires Connect* version 7.4.0 or higher. Use of Connect* versions earlier than version 7.4.0 to SELECT, UPDATE, or INSERT CLOB/BLOB data will fail and might produce unexpected application behavior and/or return an error. Connect* version 7.5.0 is compatible with versions of Model 204 that are earlier than version 7.5.0.
SOUL (User Language) enhancements
Much of the substantial new and enhanced functionality described in the following subsections is available as a result of the acquisition of Sirius Software. The functionality that is the subject of the initial subsection, "Object oriented programming," motivates the new name for User Language, SOUL, often thought of as Simple Objective User Language.
Object oriented programming
As of version 7.5 of Model 204 (and backward compatible with existing User Language applications), the SOUL language is equipped with Object-Oriented Programming (sometimes abbreviated O-O) capabilities comparable or superior to other contemporary object oriented languages. Formerly contained in the Janus SOAP User Language Interface, you can use Janus SOAP ULI essentials as a set of entry points to the extensive SOUL O-O documentation.
Record capacity increase
in this version of Model 204, the record limit is increased from sixteen million records to forty-eight million records per file.
New SOUL statements
Non O-O enhancements in SOUL
- Mixed-case SOUL
- Longstrings
- Unicode
- Double quotation marks for quoted strings
- At sign (@) on right side of assignment
- Is Defined and Is Visible tests
- Copy qualifier for subroutine parameters
- Normal syntax for LOB fields
- Implicit concatenation
- Relative values for Model 204 numeric parameters
- SOUL macro facility
- External Call support for Stringlists and $lists
External Call Facility (ECF)
EXTERNAL CALL statements can now pass more parameters. The maximum number of parameters that can be passed in an EXTERNAL CALL statement has been increased from 40 to 60. The maximum value setting for ECPSIZE is increased from 1310680 to 1966020 to accommodate the extra parameters.
REPEAT statement UNTIL option
The REPEAT statement now supports the UNTIL option. In previous releases, only REPEAT WHILE was supported.
A REPEAT UNTIL enters the loop body prior to checking the condition.
Example:
The following program results in output of '1':
BEGIN REPEAT WHILE %I EQ 0 %I = %I + 1 PRINT %I END
However, the following program results in an endless print loop:
BEGIN REPEAT UNTIL %I EQ 0 %I = %I + 1 PRINT %I END
New and changed classes and methods
New HttpRequest TranslateTable property
The TranslateTable HttpRequest property makes it possible to set the translate table to be used for EBCDIC to ASCII translation of data in an HttpRequest object.
New InvalidTranslateTable class
Objects of the InvalidTranslateTable exception class are thrown when a requested system translate table cannot be found. It is currently thrown only by the TranslateTable HttpRequest property.
New bit manipulation String functions
New bit manipulation functions BitClearString, BitCountString, BitFlipString, BitSetString, and BitValueString make it easier to manipulate the bits in a string.
New InvalidBitNumber class
Objects of the InvalidBitNumber exception class are thrown when an invalid bit number is requested by a bit manipulation function. It is currently thrown only by the BitClearString, BitFlipString, BitSetString, and BitValueString functions.
New option for AppendJournalData
The QT option is added to the AppendJournalData method, to include QT type audit entries.
New parameter for AddField
The Strip option is added to the Screen class method AddField to allow suppression of leading and trailing blank removal from input fields.
New and changed $functions
Former Sirius $functions
The $functions referred to by the link below are added to SOUL as a result of the acquisition of Sirius Software:
$SNDMAIL attachment ASCII translation
The $SNDMAIL function can now translate an attachment to ASCII before sending it. This translation is useful if the $SNDMAIL attachment is a CLOB (CHARACTER-LARGE-OBJECT) such as a text document.
The $SNDMAIL function now accepts an optional parameter after the name of the attached object. If this parameter is set to 'C' (or to a percent variable with the value 'C'), the object in the buffer is translated to ASCII before being attached to the email.
If this parameter is not specified, the object in the buffer is sent as a binary object.
In this example:
%RC = $SNDMAIL(%SUBJECT,,%BODY,%FROM,%TO,,,,'CLOB.TXT','C')
the CLOB.TXT attachment will be translated to ASCII before being attached to the email.
New products
These products are now available to Model 204 customers as separately purchased items as a result of the acquisition of Sirius Software.
Repeating field groups
[placeholder for long section to come from 7.2 rel notes]
Increased Table B record number capacity
Table B can now contain up to 48M possible record numbers. (The previous limit was 16M.)
Set FILEORG=X'200' at file creation time to allow for the increased record numbers.
Notes
- The limit for BSIZE remains at 16M.
BSIZE * BRECPPG must be less than or equal to 48M (actually decimal 50,331,648 to be exact).
For example, if BSIZE = 16M, BRECPPG cannot be less than 3. - FILEORG=X'200' cannot be specified for files with hash key or sorted file organization.
System management enhancements
Writing records to the SMF data set
Having Model 204 write records to the SMF data set no longer requires the installation of an SVC.
Therefore, the SMFSVC parameter is no longer required and, if present, will be ignored and flagged with the following informational message:
M204.0204: PARAMETER SMFSVC OBSOLETE AND NOT RESET
However, the SMFLORN and SMFSLRN parameters must still be present in CCAIN if SMF records are required.
Performance enhancements
GTBL in above the bar storage
GTBL can now be placed into non-swappable server storage area above the bar. In order to store GTBL in ATB storage:
- Increase the SERVNSSZ parameter by the GTBL size.
- Set the second byte of the SERVNSA parameter to
X’80’
, so the value of SERVNSA isX'00800000'
.
Note:
The settings for each server table above the bar are independent of each other.
So if both FTBL and GTBL are placed above the bar, then SERVNSA should be set to X'02800000'
.
MQ/204 enhancements
Freeing MQ/204 subtasks and associated storage
The new MQDELDTP PST (pseudo subtask) checks for MQ/204 subtasks that are in a delayed detach state. MQDELDTP detaches MQ/204 subtasks that have finished their work and releases their associated storage areas.
Upward compatibility issues
INTERCOMM is no longer supported
The INTERCOMM interface supports the use of Teletype and 3270 terminals in line-at-a-time mode, using the Model 204 IODEV=29 thread type.
INTERCOMM is not supported in Model 204 version 7.5.
See the Rocket Model 204 Terminal User's Guide for a discussion of terminal interfaces.
New and changed commands
DEFINE FIELD new COMMA option
The COMMA option on the DEFINE FIELD command uses commas to separate displayed field attributes.
New and changed parameters
In addition to the following specific parameter changes, Model 204 parameter descriptions, for example as displayed by the VIEW command, are now in mixed case (unless translated to uppercase due to UPCASMSG.)
ECPSIZE max value increase
The maximum value setting for ECPSIZE has been increased from 1310680 to 1966020 to accommodate more External Call Facility parameters.
OUTPUT=DUMMY for IODEV=3 threads
IODEV=3 threads definitions now allow OUTPUT=DUMMY. When defining IODEV=3 threads, if output is not required, the OUTPUT parameter can be coded as OUTPUT=DUMMY.
For example:
IODEV=3,INPUT=IOD3IN1,OUTPUT=DUMMY
This means that no DD statement is required for the output data set, and in cases where many IODEV=3 threads are defined to simulate a large number of users, this enhancement will reduce the number of DD statements required by one half.
RETRVKEY parameter change
New in this release, if you specify a non-zero setting of RETRVKEY:
- If you have set the
X'01'
orX'10'
bits of the RETRVOPT parameter, you can use a forward retrieve PF key, in addition to the backward retrieve PF key specified by RETRVKEY.Note: If either of these bits is set, the
X'02'
bit is strongly recommended as well. - The size of the allocated storage area, and hence the number and length of input lines available for retrieval, is specified by the value of the RETRVBUF parameter.
SESMAXTO new parameter
The SESMAXTO parameter can be used limit the maximum session timeout value or to cause all current closed sessions to be immediately discarded.
UPCASMSG new parameter
The UPCASMSG parameter can be used to translate messages issued by Model 204 to uppercase; otherwise (depending on the message being issued) they are displayed in mixed (upper and lower) case.
New and updated messages
M204.0141:
BUG .. DUPLICATE FILE NAME IN CP RECORD
Explanation: A duplicate file name was encountered while attempting to add a deferred update dataset to the file directory during recovery. This indicates a potential problem in the Model 204 software.
System Manager Response: Contact Customer Support with the following documentation:
- Audit trail from the previous run
- Journal from the previous run
Return Codes: E 0 4 AD OPR
M204.0204:
PARAMETER SMFSVC OBSOLETE AND NOT RESET
Explanation: Writing records to the SMF data set no longer requires the installation of an SVC. The
SMFSVC parameter is therefore obsolete and cannot be reset.
System Manager Response: No response required.
Return Codes: I 0 0 AUDITMS
Messages M204.0332 and M204.0336 indicate problems with the CRAM interface. The visibility of these messages has been improved by:
- writing the message to the operator and the JESLOG
- writing the message as an ER line in CCAAUDIT
- setting the return code to 80
M204.0332:
RC nn FROM CRFS OPEN
Explanation: The run has failed to initialize due to problems with the CRAM interface.
The possible formats of this message are:
Format 1: RC nn FROM CRFS OPEN/PUT/GET
Format 2: ECB postcode FROM CRFS PUT/GET
- Format 1 indicates that Model 204 module CRFS attempted to open channel, send a message down the channel, or receive a message from a channel. CRAM was unable to satisfy the request. The message states the return code and the operation attempted.
- Format 2 indicates that Model 204 module CRFS received an unexpected post code from CRAM while attempting an I/O operation on a channel. The message states the post code and the operation attempted.
System Manager Response: Contact Technical Support and have the audit trail available.
Return Codes: C 80 80 AUDITER NOTERM OPR
M204.0336:
RC nn FROM CRIO OPEN
Explanation: The run has failed to initialize due to problems with the CRAM interface.
The possible formats of this message are:
Format 1: RC nn FROM CRIO OPEN/PUT/GET
Format 2: ECB postcode FROM CRFS PUT/GET
- Format 1 indicates that Model 204 module CRIO attempted to open a channel, send a message down a channel, or receive a message from a channel. CRAM was unable to satisfy the request. The message states the return code and the operation attempted. For example, the return code 16 indicates that the CRAM channel is already open.
- Format 2 indicates that Model 204 module CRFS received an unexpected post code from CRAM while attempting an I/O operation on a channel. The message shows the post code and the operation attempted.
System Manager Response: Contact Technical Support and have the audit trail available.
Return Codes: C 80 80 AUDITER NOTERM OPR
M204.0434:
NJBUFF SET TO %C
Explanation: TBD
M204.0790:
FILE TOO BIG
Explanation: The total number of records possible in Table B exceeds 342 segments for files that do not have the FILEORG X'200' bit set and 1024 segments for files that have the FILEORG X'200' bit set.
The number of potential record numbers per segment is 49,152.
The number of possible segments in Table B is calculated by the following formula:
((BSIZE * BRECPPG) / 49,152)) + (1 if remainder not 0)
If the result exceeds 342 or 1024 respectively too many segments result and MODEL 204 rejects the CREATE command.
File Manager Response: Make the file smaller (by specifying a smaller BSIZE or smaller BRECPPG), or divide the file into smaller pieces and use the file group feature to process them as a single logical file.
Return Codes: C 0 4 AUDITER
M204.0797:
BSIZE*BRECPPG EXCEEDS MAXIMUM VALUE
Explanation: The product of BSIZE and BRECPPG must not exceed 16,777,216 for regular Model 204 files (which do not have the FILEORG X'200' bit set) and 50,331,648 for files that have the FILEORG X'200' bit set. These numbers specify the maximum number of records allowed in a single Model 204 file.
The CREATE or INCREASE command is rejected.
File Manager Response: Retry the command, specifying values for BSIZE and BRECPPG so that BSIZE*BRECPPG does not exceed the limit. Refer to the Rocket Model 204 File Manager's Guide for more information on file sizes.
Return Codes: C 0 4 AUDITER
M204.1052:
LOUTPB %C TO %C
Explanation:
LOUTPB has been increased or decreased, to the value given in the message.
With a full-screen terminal the value is 1.5 times the minimum for that model number, rounded
up to a multiple of 8.
A model 2 terminal results in a LOUTPB of 3200.
A model 5 terminal results in a LOUTPB of 5664.
If NBKPG is greater than 0, the largest allowable value for LOUTPB is PAGESZ minus 40, so the value can be decreased for this reason.
User Response: No response is needed. This message is for information only.
Return Codes: I 0 0 AUDITAD
M204.1131:
CAN'T action
Explanation: The procedure action cannot be taken for one of the following reasons:
- The procedure is in use by another user.
- The procedure is not in the file.
- The user does not have the correct privileges to change the procedure.
- If a RENAME or ASSIGN has been attempted, the alias might already exist.
Response: Make sure that the procedure name is spelled correctly.
If the named procedure is in use, retry the command when the procedure is no longer in use. Otherwise, arrange to place the
procedure in the file or to obtain the privileges to change the procedure.
Return Codes: C 0 4 SUFFIX AUDITER
M204.1260:
{FIELD | FIELDGROUP] WAS PREVIOUSLY DEFINED WITH DIFFERENT ATTRIBUTES, NEW [FIELD | FIELDGROUP] OPTIONS IGNORED
Explanation: A DEFINE [FIELD | FIELDGROUP] command has attempted to define an existing field with different attributes.
Response: If you wish to redefine the attributes of the field, you must issue the REDEFINE [FIELD | FIELDGROUP] command. Notify your file manager.
Return Codes: C 0 4 AUDITER
M204.1307:
%C LOGON REJECTED - reason text (REASON CODE: %X)
Explanation: The MODEL 204 3270 terminal handler has rejected a logon request from a 3270 terminal for the reason stated. The following reason codes are defined:
- There are no control blocks available for new logons. Increase the number of IODEV 7 terminal definitions. The reason text is: NOT ENOUGH 3270 TERMINALS.
- The terminal has been defined with a non-3270 transmission services profile. The LU type must be 2.
- The reason text is: LU TYPE NOT = 2.
- The terminal has been defined to require definite responses to messages it sends inbound to the host. The transmission services profile must be 3. The reason text is: TS PROFILE NOT = 3.
- There has been an error on this terminal. This is a retryable error. The reason text is: LOSTERM SET FOR THIS TERMINAL.
- The terminal definition is in use. This error should not occur. The reason text is: TERMINAL ALREADY IN USE.
System Manager Response: Contact your VTAM systems programmer to correct the VTAM definition.
Return Codes: E 0 4 AD SAVE NOTERM OPR
M204.1393:
CHUNK clause not of format "CHUNK chunkSize FOR chunkTarget"
Explanation: On a DEFINE FIELD, the syntax of the CHUNK clause was not in the format shown in this message.
File Manager Response: Correct the DEFINE FIELD command that has the incorrect CHUNK clause syntax.
Return Codes: C 0 4 AUDITER
M204.1394:
CHUNK chunkSize VALUE INVALID: reason
Explanation: On a DEFINE FIELD, the value specified for the size of a CHUNK is invalid;
"reason" indicates why.
File Manager Response: Correct the DEFINE FIELD command that has the invalid CHUNK size.
Return Codes: C 0 4 AUDITER
M204.1395:
CHUNK target is not VISIBLE ORDERED NUMERIC
Explanation: On a DEFINE FIELD, the field specified as a CHUNK target is not VISIBLE ORDERED NUMERIC, which is a requirement of chunk fields.
File Manager Response: Correct the DEFINE FIELD command that has the invalid CHUNK target type.
Return Codes: C 0 4 AUDITER
M204.1396:
CHUNK fields must be INVISIBLE ORDERED NUMERIC
Explanation: On a DEFINE FIELD, an attempt was made to create a CHUNK field that was not INVISIBLE ORDERED NUMERIC, which is a requirement of chunk fields.
File Manager Response: Correct the DEFINE FIELD command that has the invalid CHUNK target type.
Return Codes: C 0 4 AUDITER
M204.1397:
A CHUNK field was defined, %F may no longer be opened with M204 releases prior to V7R5
Response: This is an informational message. No action is required.
Return Codes: I 0 0 AUDITMS
M204.1489:
NOT ENOUGH FILE SPACE TO CONTINUE PROCEDURE DEFINITION - %F
Explanation: There is no room in the file to store the procedure being entered with the PROCEDURE command.
If… | Then Model 204… |
Error occurs after the first line of procedure text has been stored | Keeps the partial procedure |
You are entering the text at your terminal | Ends procedure definition immediately |
Procedure text is supplied by another procedure | Flushes the remainder of the input |
Procedure text is supplied in a batch input stream (CCAIN) | Flushes the remainder of the procedure text and resumes processing after the END PROCEDURE command |
Response: Create space in the file by deleting unwanted procedures or increasing Table D with the INCREASE command. Replace the partial procedure using the PROCEDURE command, or use the EDIT command to supply the missing text.
Return Codes: C 0 4 CANCEL AUDITER
1938:
REQUEST FOR SPACE IN TABLE E EXTENDS BEYOND EHIGHPG, BIT MAP PAGES ARE SCANNED FOR FREESPACE
Explanation: A User Language request attempted to store a large object and all of the append pages in Table E have been allocated. Model 204 must scan the bit map pages for previously allocated Table E pages to look for free space to store the large object.
File manager response: The file should be reorganized to compact fragmented Table E space.
Return Codes: I 0 0
M204.2126:
USER'S PUSHDOWN LIST OVERFLOWED
Explanation: The user's pushdown list is an internal stack for maintaining state information for user threads across internal Model 204 subroutines. The user pushdown list lives in each user's server. Its size requirement depends on the complexity of the command or User Language request.
This message is issued whenever Model 204 detects that pushdown list data has spilled into adjacent control structures. Because of potential corruption the user is restarted.
Response: Increase the size of the user pushdown list by using the LPDLST parameter of the UTABLE command. Notify your system manager.
System Manager Response: If this becomes a frequent occurrence, consider more permanent changes to LPDLST and SERVSIZE, since the pushdown list is a server component.
Return Codes: C 0 4 CANCEL
M204.2329:
subsystem name AT location name UNAVAILABLE
Explanation: The indicated subsystem at the specified node is not available for use due to one or more errors occurring at the specified node during start or login processing.
Response: Notify the system manager or try again later.
System manager response: If the subsystem is started, stop the subsystem and resolve communications errors or other errors which occurred at the specified node. After resolving error, use the START SUBSYSTEM command to make the subsystem available for general use. Check to make sure that the LOCATION parameter was set properly in the CCAIN input stream for the Online.
Return Codes: C 0 4
M204.2551:
{FPL|FCT PG1} IS INVALID FOR FILE: filename
Explanation: If the message says FPL, then the FPL (file parameter list) for the associated file is invalid. This could be the result of an incorrect DD, FILEDEF or DLBL statement.
If the message says FCT PG1, then the existence page array page is invalid.
File Manager Response: If the DD, FILEDEF or DLBL statement is correct and points to the correct data set, then the file must be restored from a backup.
Return Codes: C 0 4 AUDITER
M204.2651:
NOT ALL THREADS PROCESSED FOR IODEV %C
Explanation: The run is terminated because either:
- The number of threads specified by NUSERS has been initialized, but there are fewer users of the specified IODEV type than expected.
- The DUPTERM number specified by the IODEV card could not be initialized because it exceeded the number of NUSERS.
Response: Check that NUSERS matches the total of the listed IODEVs, plus one extra for USER 0. Check also the NOTERM/DUPTERM parameter for the specified IODEV card.
Return Codes: E 80 80 ER
M204.2719:
OPEN %C FAILED. UPDATE STATEMENTS ALREADY COMPILED, READ ONLY PRIVILEGES INSUFFICIENT
Explanation: The OPEN or OPENC User Language statement was issued from a request to reopen a file with read-only privileges. However, that request had already been compiled with update statements against the file.
Response: In a User Language request, you cannot use the User Language OPEN or OPENC statement to reopen a file with read-only privileges, if that request contains updates statements against the same file.
Descriptor code: C 0 4 CANCEL
M204.2739:
PARAMETER parm CANNOT BE RESET ON USER 0’S PARAMETER LINE: VALUE IGNORED
Explanation: You reset parameter parm on the User 0 parameter line, but the parameter cannot be set there. The value is ignored, the default value for this parameter remains in effect.
Response: Remove parm from the User 0 parameters, since it will not change the value of the parameter.
Descriptor code: E 0 4 AD
M204.2746:
XSIZE*XRECPPG MAY NOT BE 1 NOR EXCEED 536870911
Explanation: The product of XSIZE and XRECPPG must not exceed 16777216 times 32 minus one, or 536870911. This specifies the maximum number of extension records allowed in a single Model 204 file when using Table X. Also, setting both XRECPPG and XSIZE to 1 is invalid.
The CREATE command is rejected.
Response: Retry the command specifying values for XSIZE and XRECPPG whose product does not exceed the 526870911 limit. Refer to the Rocket Model 204 File Manager’s Guide for more information on file sizes.
Descriptor code: C 0 4
M204.2826:
%F VERSION IS PRE 6.3. COMPACTION NOT ALLOWED
Explanation: An attempt was made to compact a file created prior to Model 204 version 6.3.
File Manager Response: Reorganize the file using Model 204 version 6.3.
Return Codes: C 0 4 AUDITER
M204.2831:
UPDATES TO DTS FILES NOT SUPPORTED IN THIS ENVIRONMENT
Explanation: DTS files cannot be updated in IFAM, SQL, or PQO environments.
Response: Do not attempt to update DTS file.
Return Codes: C 0 4
M204.2833:
FIELDS CANNOT BE DEFINED IN A FILE WITH ATRPG*ASTRPPG>4000
Return Codes: C 0 4
M204.2836:
VALUE OF PARAMETER %C INVALID—RESET TO %C
Explanation: This is an informational message only.
A parameter was specified with an incorrect value. It has been reset to an internally calculated value that will accommodate other parameter settings. See the description of the parameter named to see what that calculation involves.
System Manager Response: The parameter has been reset. No response required.
Return Codes: I 0 0 AUDITMS
2838: %C ONLY VALID IN FILEORG X’100’ FILES
Return Codes: C 0 4
2839: %C IS A %C, NOT A %C
Return Codes: C 0 4 ECHO
2841: REMOTE FIELDGROUPS NOT SUPPORTED
Return Codes: C 0 4 ECHO
2842: INVALID CONTEXT FOR FIELDGROUP
Return Codes: C 0 4 ECHO
2843: MAXIMUM FIELDGROUP ID EXCEEDED IN RECORD %R IN %F
Return Codes: C 0 4 CANCEL
2844: MIX OF FIELDS AND FIELDGROUPS, NAME =
Return Codes: C 0 4 SUFFIX ECHO
2845: INVALID FIELDGROUP CONTEXT FOR %C
Explanation: The $function was used outside of field group context.
Descriptor code:C 0 4 SUFFIX ECHO
2846: INVALID FIELDGROUP CONTEXT FOR %C
Return Codes: C 0 4 CANCEL
2847: FIELDGROUP CONTEXT LOST IN RECORD %R IN %F
Return Codes: C 0 4 CANCEL
2848: INVALID FIELDGROUP ID: %C
Return Codes: C 0 4 CANCEL
2849: REQUIRED KEYWORD %C MISSING
Return Codes: X 0 4 ECHO
2850: %C VALUE MISSING
Return Codes: C 0 4
2851: %C VALUE "%C" TOO BIG, MUST BE <%C BYTES
Return Codes: C 0 4
2852: UPDATE TO MISSING FIELDGROUP OCCURRENCE IN RECORD %R IN %F
Return Codes: C 0 4 CANCEL
2853: %C NOT ALLOWED FOR EXACTLY-ONE FIELD
Return Codes: C 0 4
2854: ATTEMPT TO DO %C FOR EXACTLY-ONE FIELD: %C
Return Codes: C 0 4 CANCEL
2855: FIELD DEPTH+LENGTH UNREPRESENTABLE IN RECORD %R IN %F
Return Codes: C 0 4 CANCEL
2856: FIELDNAME VARIABLE %C: EXPECTED %C, GOT %C
Return Codes: C 0 4 CANCEL
2857: %C FIELD NOT ALLOWED FOR %C FIELD
Return Codes: C 0 4
2858: FIELDGROUP CONTEXT MISMATCH BETWEEN COUNTOCCURRENCES- OF FIELD AND COUNTED FIELD
Return Codes: C 0 4
2859: NEW AUTOMATIC FIELD NOT ALLOWED FOR NON-EMPTY FILE
Return Codes: C 0 4
2860: FIELD %C ALREADY HAS A COUNT-OCCURRENCES-OF FIELD
Return Codes: C 0 4
2861: OCCURRENCE COUNTER %C OVERFLOWED
Return Codes: C 0 4 CANCEL
2862: ATTEMPT TO UPDATE AUTOMATIC FIELD %C
Return Codes: C 0 4 SUFFIX ECHO
2863: ATTEMPT TO DO %C FOR AUTOMATIC FIELD: %C
Return Codes: C 0 4 CANCEL
2865:CANCELATTEMPT TO %C INVALID DATETIME VALUE: %C = %C'
Return Codes: C 0 4 CANCEL
2866: FILE ALREADY HAS %C FIELD
Return Codes: C 0 4
2867: FIELDGROUP %C ALREADY HAS %C FIELD
Explanation: If you try to define a second update tracker field of the same type for the same field group, you will invoke message 2867, where %C represents:
- A CREATE-TIME
- A CREATE-TIMEUTC
- A CREATE-USER
- AN UPDATE-TIME
- AN UPDATE-TIMEUTC
- AN UPDATE-USER
Return Codes: C O 4
2868: MINLOBE MUST BE BETWEEN 0 AND %C'
Return Codes: C 0 4
M204.2869:
CHANGE REFUSED: MINLOBE > 0 FOR %F FIELD %C
Return Codes: C 0 4 AUDITER
M204.2870:
CHANGE REFUSED: MINLOBE > 0 FOR %F FIELD %C
Return Codes: C 0 4 CANCEL AUDITER
2871: FIELDGROUP CONTEXT MISMATCH BETWEEN CONCATENATION-OF FIELD AND COMPONENT FIELD'
Return Codes: C 0 4
2872: CONCATENATION VALUE TOO LONG FOR FIELD %C'
Return Codes: C 0 4 CANCEL
2873: CONCATENATION FIELD %C COMPONENT FIELD %C CONTAINS SEPARATOR CHARACTER'
Return Codes: C 0 4 CANCEL
2874: ATTEMPT TO %C A VALUE THAT'S %C: %C
Return Codes: C 0 4 CANCEL
2875: CONCATENATION LIST INVALID: %C'
Return Codes: C 0 4
2876: INVALID %C VALUE: %C'
Return Codes: C 0 4
2877: WITH CLAUSE INVALID: %C'
Return Codes: C 0 4 ECHO
2878: WITH CLAUSE INVALID: FIELD %C IN %F %C
Return Codes: C 0 4 CANCEL
2879: REMOTE ID %C MODE %C'
Return Codes: I 0 0 SAVE NOTERM OPR
2880: MEMORY DATASETS CANNOT BE PART OF MULTI-DATASET FILE
Return Codes: C 0 4
2881: DATA CONVERSION ERROR
Return Codes: C 0 4 CANCEL
2882: RECOVERY JOURNAL VERSION %X IS NOT SUPPORTED
Return Codes:E 0 4 OPR
2884: [FIELD | FIELDGROUP] WAS PREVIOUSLY DEFINED AS A [FIELDGROUP | FIELD], NEW DEFINITION IGNORED
Return Codes: C 0 4
2885: INVALID FIELDGROUP ID: fieldgroup
Return Codes: C 0 4 CANCEL
2886: FIELDGROUP ID %C ALREADY EXISTS IN RECORD %R IN %F'
Return Codes: C 0 4
2903: FILEORG=X'100' IS NOT SUPPORTED DURING FLOD/FILELOAD
Return Codes: E 0 8
M204.2933:
'Module version mismatch, KOMM=%C, %C=% C'
Return Codes: E 0 4 SNAP
M204.2934:
FILEORG X''200'' not supported for hashed or sorted file organizations
Explanation: Hashed or sorted files must be 16M files. The CREATE FILE command
is rejected.
File Manager Response: Remove the conflicting FILEORG parameter and reissue CREATE FILE.
Return Codes: E 0 4 AUDITMS
M204.2935:
{CHUNK|CHUNK target} FIELDS MAY NOT BE RENAMED OR DELETED
File Manager Response: Do not attempt to RENAME or DELETE chunks or chunk targets.
Return Codes: C 0 4 AUDITER
M204.2936:
A CHUNK FIELD OF SIZE nnn ALREADY EXISTS FOR THIS FIELD
Explanation: For a given CHUNK target field, duplicate chunk sizes are not permitted.
File Manager Response: Correct the DEFINE FIELD that caused the message.
Return Codes: C 0 4 AUDITER
M204.2937:
CHUNK SIZE: nnn IS NOT AN INTEGRAL MULTIPLE/DIVISOR OF THE EXISTING CHUNK SIZE: nnn
Explanation: A CHUNK field's chunk size must be an integral multiple/divisor of all other chunk's sizes for a given chunk target.
This message identifies the existing chunk size that conflicts with the new one.
File Manager Response: Correct the DEFINE FIELD that caused the message.
Return Codes: C 0 4 AUDITER
M204.2938:
YOU MAY NOT DEFINE MORE THAN 20 CHUNKS FOR A FIELD
Explanation: A given chunk target can have at most 20 chunks defined.
File Manager Response: Do not try to define more than 20 CHUNK fields for any given CHUNK target field.
Return Codes: C 0 4 AUDITER