Search results

Jump to navigation Jump to search

Google site results

Loading...

Wiki results

  • ...L, and the EXTENT statements for CCAGEN are missing from the z/VSE or z/OS JCL for your regeneration run. For the CMS version of Model 204, the FILED ...BL, and the EXTENT statements for CCARF are missing from the z/OS or z/VSE JCL for your recovery run. For the CMS version of Model 204, the FILEDEF s ...
    1 KB (196 words) - 22:28, 6 March 2018
  • ...E phase during [[Model 204 installation on IBM z/VSE|installation on IBM z/VSE]]. ====LINKONLN JCL example==== ...
    2 KB (196 words) - 16:58, 23 April 2018
  • ...ent for the CMS version, or incorrect DLBL and EXTENT statements for the z/VSE version. </P> <b>System manager response:</b> Correct your z/OS or z/VSE JCL or CMS EXEC statement for the file in question. Otherwise, contact [[Contac ...
    915 bytes (151 words) - 03:24, 23 February 2018
  • ...s. For z/OS users, MAXTIME is set to the time specified on the JOB or EXEC JCL statement parameter TIME. MAXTIME is used with <var>[[TIMELEF_parameter|TIM ...an exceed 24 hours under z/OS. If TIME is set to 1440 (that is, 24 hours), z/OS does not automatically shut down <var class="product">Model&nbsp;204</va ...
    1 KB (221 words) - 13:45, 4 August 2015
  • ...nformation to open the data set by verifying that the JCL (under z/OS or z/VSE) or FILEDEF (under CMS) specifies the correct data set name and disk addres If the JCL or FILEDEF is correct, determine whether the data set has been erased or is ...
    750 bytes (124 words) - 23:01, 6 March 2018
  • <li>PARM field in the JCL EXEC statement (z/OS) <li>EXEC that issues all the FILEDEFs (z/VM)</li> ...
    2 KB (338 words) - 19:27, 6 January 2017
  • <li>For z/OS systems, insert a DD statement for CCASTAT into your startup JCL and rerun Model&nbsp;204. </li> ...stems, insert the DLBL and EXTENT statements for CCASTAT into your startup JCL and rerun Model&nbsp;204. </li> ...
    959 bytes (156 words) - 23:32, 22 February 2018
  • This message applies only to the z/VSE version of Model&nbsp;204. The symbolic unit number specified for a data se ...files, verify that the symbolic user number (SYS<i>nnn</i>) used as the z/VSE file name on the TLBL statement is assigned to a tape drive. </P> ...
    797 bytes (140 words) - 23:35, 6 March 2018
  • ...library during [[Model 204 installation on IBM z/VSE|installation on IBM z/VSE]]. /* ASSGN - this jcl assumes standard assignments ...
    2 KB (194 words) - 16:58, 23 April 2018
  • ...tatements (z/VSE) point to the correct data sets. If you are running under z/VM CMS, verify that the FILEDEF statement(s) in your EXEC procedure are ...
    769 bytes (131 words) - 15:52, 7 March 2018
  • <td>z/OS</td> ...7.5 and later: The distributed macro library <br>Pre-V7.5: The distributed JCL library </td> ...
    1 KB (232 words) - 17:06, 15 June 2018
  • ...INT defines a sequential output data set (usually <code>SYSOUT=*</code> in z/OS) that contains User 0 output, such as:</p> ===z/OS considerations=== ...
    3 KB (539 words) - 17:08, 6 November 2014
  • ...el&nbsp;204</var> files, including CCATEMP, CCAGRP, and CCASERVR, in the z/VSE environment. One or more files, as specified in control statements, can be ...CATE statement control does not have a corresponding DLBL statement in the JCL, an error message is logged in the output audit trail. </li> ...
    2 KB (329 words) - 17:30, 20 November 2014
  • Under VS1 or z/OS, the <var class="term">token</var> entity has not been allocated, or acc Under z/VSE, <var class="term">token</var> cannot be opened for one of the following re ...
    3 KB (489 words) - 19:49, 26 March 2018
  • ...statements (z/VSE) point to the right data sets. If you are running under z/VM CMS, verify that the FILEDEF statement(s) in your EXEC procedure are cor ...
    1,009 bytes (172 words) - 04:31, 1 March 2018
  • The name, from a FILEDEF or a JCL file assignment, of an output file</p> <var>OUTPUT</var> and <var>INPUT</var> must match the names from FILEDEF or JCL file assignments:</p> ...
    1 KB (240 words) - 01:58, 14 March 2017
  • ...cedures during [[Model 204 installation on IBM z/VSE|installation on IBM z/VSE]]. * M204JCL PROC: ACCESS THE M204 JCL SUBLIB ...
    2 KB (243 words) - 16:59, 23 April 2018
  • <p>For z/VM and z/VSE, <var class="product">Model&nbsp;204</var> execution time cannot exceed 24 ...EXEC statement parameter TIME. If TIME is set to 1440 (that is, 24 hours), z/OS does not automatically shut down <var class="product">Model&nbsp;204</va ...
    2 KB (273 words) - 12:46, 28 September 2017
  • ...de>, referring to the run's data definition statement in the z/OS or z/VSE JCL, or to the FILEDEF statement in the CMS EXEC. Output name can also be the n ...
    1 KB (206 words) - 21:14, 16 January 2018
  • ...am) is correctly coded and the named data sets exist in the system. (For z/VSE users, instead of DD statements and data set names, DLBL and EXTENT stateme ...
    949 bytes (166 words) - 23:45, 7 March 2018
  • <td>z/OS</td> ...7.5 and later: The distributed macro library <br>Pre-V7.5: The distributed JCL library </td> ...
    4 KB (713 words) - 16:32, 3 July 2018
  • ==Installation on IBM z/OS== ...tion describes the SoftSpy installation steps that are specific to the IBM z/OS operating system. ...
    16 KB (2,650 words) - 19:12, 25 April 2017
  • <p>For HDR2, the default under z/VM is the first eight characters of the <var class="product">Model&nbsp;204 The z/VSE/POWER equivalent option name is FNO.</p> ...
    15 KB (2,655 words) - 22:53, 17 October 2017
  • <p>See [[Model 204 installation on IBM z/OS#Installing the UL/DB2 interface (JAUSQLJ job stream)|installing the UL/D The following figure shows the UL/DB2 program environment under IBM z/OS. ...
    4 KB (631 words) - 21:03, 6 February 2017
  • ...ar destinations without using specific data set definitions in the startup JCL.</p> ...e command summaries are sections that explain how to direct output using z/VSE/POWER and how to print separator pages in block format.</p> ...
    36 KB (6,123 words) - 21:07, 6 February 2017
  • ...being updated and the number of deferred update data sets specified in the JCL. The File Load can have three, five, or seven steps. The [[Deferred update The JCL for the first phase of the multistep version normally includes the statemen ...
    17 KB (2,694 words) - 21:36, 7 April 2017
  • <p class="note"><b>Note:</b> Due to a z/VM limitation, the LRECL maximum is 204 bytes.</p> ...ar> separator page is printed in addition to the separators generated by z/VSE/POWER when JOBSEP is specified. </p> ...
    23 KB (4,029 words) - 15:53, 12 February 2019
  • ...uct">Model&nbsp;204</var>. Access to VSAM files is supported in z/OS and z/VSE versions of <var class="product">Model&nbsp;204</var>.</p> ...dance with the BSAM data set structure (z/OS) or the SAM file structure (z/VSE): </p> ...
    15 KB (2,554 words) - 17:08, 6 November 2014
  • ...age such as <code>SYNCSORT</code>. It can be used on the z/OS, z/VM, and z/VSE operating systems, and supports fixed and variable record format files.</p> ====For z/OS==== ...
    24 KB (4,144 words) - 20:51, 20 March 2018
  • ===z/OS and IFAM1=== The following considerations apply to the z/OS JCL required to run IFAM1:</p> ...
    26 KB (4,108 words) - 21:25, 19 June 2018
  • <var class="product">Dictionary/204</var>, whether for z/VM CMS, z/OS, or z/VSE. ...#Installing Dictionary/204 on IBM z/VSE|Installing Dictionary/204 on IBM z/VSE]] describe these steps in greater detail for each operating system. ...
    26 KB (4,206 words) - 16:12, 26 September 2017
  • ...llowing sequence of commands to rename a file named CANINES to DOGS. (In z/VSE you must have previously defined both file IDs in the job because there is ...le named DOGS. It is the user's responsibility to change the corresponding JCL, if needed, to the proper DDNAME.</p> ...
    4 KB (779 words) - 20:50, 1 March 2024
  • ...updated and the number of deferred index update data sets specified in the JCL.</li> The one-step File Load is not available under z/VSE. </p> ...
    9 KB (1,571 words) - 20:38, 15 December 2014
  • <tr><td style=white-space:nowrap>IFIF <br />IFIFDOS (for VSE)</td> <td>Supports IFAM2</td> <td /></tr> ...If you are using [[Defining the user environment (CCAIN)#CRAM options for z.2FOS|CRAM-XDM]], you can run the above programs in <code>USER</code> key. H ...
    11 KB (1,914 words) - 23:12, 5 April 2017
  • ...that creates such a file from a preallocated data set for z/OS, z/VSE, and z/VM operating systems are illustrated in this section.</p> ====z/OS example==== ...
    15 KB (2,436 words) - 20:26, 26 September 2016
  • <li>Run z/OS in 64-bit mode and have real storage larger than 2-gigabytes</li> ...spaces with no excessive paging. A <b>dataspace</b> is an address space in z/OS with none of the control structures for tasks; it is simply data.</li> ...
    13 KB (2,161 words) - 18:20, 16 August 2016
  • The one-step File Load is not available under z/VSE. </p> Under z/VM, the one-step File Load is run by a single command (FASTLOAD) that drive ...
    13 KB (2,199 words) - 22:48, 12 January 2015
  • ===z/OS procedures=== In a z/OS environment, take the following steps to create CCAGRP: </p> ...
    19 KB (3,156 words) - 17:08, 6 November 2014
  • ...TCH204 module contains the DUMP/RESTORE utility. In addition to the normal JCL or EXEC that the system manager supplies to run BATCH204, the DUMP command ===z/OS considerations=== ...
    34 KB (5,868 words) - 21:49, 24 July 2017
  • ====RESTART under z/VSE==== Under z/VSE, the <var>DEFINE DATASET</var> command must precede the User 0 parameter li ...
    12 KB (1,961 words) - 22:16, 31 October 2017
  • ...install Rocket Model 204 version 7.5 or later on an IBM<sup>&reg;</sup> z/VSE<sup>&reg;</sup> operating system. <li>If your z/VSE site runs under z/VM, copy and link the [[#bvp204|$$BVP204]] phase.</li> ...
    37 KB (6,036 words) - 18:18, 1 June 2017
  • Sites with z/OS can also define the checkpoint and journal data streams with GDG data se ...off load stream for z/OS|Example 3: Concatenated tape off load stream for z/OS]] section. ...
    37 KB (6,120 words) - 23:58, 29 March 2016
  • <li>Under z/OS, VSE, CMS</li> <li>Under z/OS, VSE, CMS</li> ...
    53 KB (8,684 words) - 20:02, 3 April 2017
  • ===z/OS procedures=== Use the following z/OS JCL to create CCASTAT:</p> ...
    38 KB (6,272 words) - 04:08, 12 March 2019
  • <li> Setting up and maintaining the OS or DOS JCL or CMS EXECs and <var class="product">Model&nbsp;204</var> parameters for t ...>Model&nbsp;204</var> is compatible with all versions of z/OS, z/VM, and z/VSE currently supported by IBM. For details, see [[Model 204 system requirement ...
    23 KB (3,553 words) - 21:46, 1 May 2017
  • ...g open processing. Because dynamic allocation is valid only under z/OS and z/VM, these options therefore are ignored under other operating systems.</p> ...overwritten. The default is NOAPPEND. This option is not supported under z/VSE. </td> </tr> ...
    47 KB (8,047 words) - 16:32, 11 February 2019
  • ...e downloaded to the workstation, they must be uploaded to the z/OS, VM, or VSE system on the IBM mainframe. ...must be <code>F</code> under VM systems and <code>FB</code> under z/OS and VSE systems. The LRECL must be ...
    32 KB (5,073 words) - 21:01, 2 August 2021
  • ...dress space or virtual machine (ONLINE module) in the IBM z/OS, z/VSE, and z/VM operating systems. The [[Connect*|Connect<span class="superstar">&#9733; <li>Update access to the JCL or EXECs that bring up the host Online.</li> ...
    14 KB (2,230 words) - 22:29, 27 April 2018
  • ...CCATEMP in recovery, and summarizes job control information for z/OS and z/VSE environments. </p> ...ary file, overwrite it in a prior job step using IEBGENER (z/OS), DITTO (z/VSE), or the CMS FORMAT command to avoid the possibility of receiving an old sc ...
    16 KB (2,627 words) - 18:53, 8 June 2017
  • <li>Include a CCAJRNL data set or file definition statement in the JCL or EXEC for the run. (If multiple journal data sets are generated, addition The MERGEJ utility allows as many as 32 journal files (9 for z/VSE systems) to be combined into one file. The number of journal files that can ...
    43 KB (7,213 words) - 22:23, 28 September 2016
View (previous 50 | ) (20 | 50 | 100 | 250 | 500)