<p> | <p> | ||
<p>Valid settings of IODEV are:</p> | <var>IODEV</var> specifies the input/output device type.</p> | ||
<p> | |||
Valid settings of <var>IODEV</var> are: | |||
</p> | |||
<table> | <table> | ||
<tr class="head"><th>IODEV</th><th>Access method/device type</th></tr> | <tr class="head"><th>IODEV</th> | ||
<tr><th align="right"><var> 1</var></th><td>CCAIN/CCAPRINT (User 0 only)</td></tr> | <th>Access method/device type</th></tr> | ||
<tr><th align="right"><var> 3</var></th><td>BSAM</td></tr> | |||
<tr><th align="right"><var> 7</var></th><td>SNA Communications Server 3270</td></tr> | <tr><th align="right"><var> 1</var></th> | ||
<tr><th align="right"><var>11</var></th><td>Remote User Language thread (full screen) </td></tr> | <td>CCAIN/CCAPRINT (User 0 only)</td></tr> | ||
<tr><th align="right"><var>19</var></th><td>VTAM or TCP/IP (Horizon SQL thread)</td></tr> | |||
<tr><th align="right"><var>23</var></th><td>Host Language IFAM thread</td></tr> | <tr><th align="right"><var> 3</var></th> | ||
<tr><th align="right"><var>25</var></th><td>[[Fast/Unload Soul Interface|FUSI]] thread, new in version 7.6 of Model 204. These are created implicitly; as many threads are created as is the value of the <var>[[FUNTSKN parameter|FUNTSKN]]</var> parameter. There is no reason to attempt to define these threads explicitly.</td></tr> | <td>BSAM (see Uses of IODEV=3 at [[Defining the user environment (CCAIN)]])</td></tr> | ||
<tr><th align="right"><var>27</var></th><td>VTAM (Horizon thread)</td></tr> | |||
<tr><th align="right"><var>29</var></th><td>Remote User Language thread (line-at-a-time)</td></tr> | <tr><th align="right"><var> 7</var></th> | ||
<tr><th align="right"><var>37</var></th><td>SNA Communications Server 3767 and NTO (z/OS) | <td>SNA Communications Server 3270</td></tr> | ||
<p class="note"><b>Note:</b> Value 37 is | |||
<tr><th align="right"><var>39</var></th><td>IUCV User Language thread (line-at-a-time)</td></tr> | <tr><th align="right"><var>11</var></th> | ||
<tr><th align="right"><var>41</var></th><td>IUCV User Language thread (full screen)</td></tr> | <td>Remote User Language thread (full screen) </td></tr> | ||
<tr><th align="right"><var>43</var></th><td>IUCV Host Language Interface thread</td></tr> | |||
<tr><th align="right"><var>45</var></th><td>CMS line-at-a-time console. This z/VM device setting is an <var>[[ALTIODEV_parameter|ALTIODEV]]</var> value; is cannot be specified on the user's parameter line.</td></tr> | <tr><th align="right"><var>19</var></th> | ||
<tr><th align="right"><var>47</var></th><td>CMS full screen console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. </td></tr> | <td>VTAM or TCP/IP (Horizon SQL thread)</td></tr> | ||
<tr><th align="right"><var>49</var></th><td>VTAM or TCP/IP Horizon Remote Command Line (RCL) thread.</td></tr> | |||
<tr><th align="right"><var>51</var></th><td>SNA Communications Server (Parallel Query Option/204 thread)</td></tr> | <tr><th align="right"><var>23</var></th> | ||
<td>Host Language IFAM thread</td></tr> | |||
<tr><th align="right"><var>25</var></th> | |||
<td>[[Fast/Unload Soul Interface|FUSI]] thread, new in version 7.6 of Model 204. These are created implicitly; as many threads are created as is the value of the <var>[[FUNTSKN parameter|FUNTSKN]]</var> parameter. There is no reason to attempt to define these threads explicitly.</td></tr> | |||
<tr><th align="right"><var>27</var></th> | |||
<td>VTAM (Horizon thread)</td></tr> | |||
<tr><th align="right"><var>29</var></th> | |||
<td>Remote User Language thread (line-at-a-time)</td></tr> | |||
<tr><th align="right"><var>37</var></th> | |||
<td>SNA Communications Server 3767 and NTO (z/OS) | |||
<p class="note"><b>Note:</b> Value 37 is no longer supported as of Model 204 version 7.6.</p></td></tr> | |||
<tr><th align="right"><var>39</var></th> | |||
<td>IUCV User Language thread (line-at-a-time)</td></tr> | |||
<tr><th align="right"><var>41</var></th> | |||
<td>IUCV User Language thread (full screen)</td></tr> | |||
<tr><th align="right"><var>43</var></th> | |||
<td>IUCV Host Language Interface thread</td></tr> | |||
<tr><th align="right"><var>45</var></th> | |||
<td>CMS line-at-a-time console. This z/VM device setting is an <var>[[ALTIODEV_parameter|ALTIODEV]]</var> value; is cannot be specified on the user's parameter line.</td></tr> | |||
<tr><th align="right"><var>47</var></th> | |||
<td>CMS full screen console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. </td></tr> | |||
<tr><th align="right"><var>49</var></th> | |||
<td>VTAM or TCP/IP Horizon Remote Command Line (RCL) thread.</td></tr> | |||
<tr><th align="right"><var>51</var></th> | |||
<td>SNA Communications Server (Parallel Query Option/204 thread)</td></tr> | |||
</table> | </table> | ||
Latest revision as of 23:57, 10 January 2018
Type of I/O device
Summary
- Default value
- 1
- Parameter type
- User
- Where set
- On user's parameter line
- Related products
- All
- Introduced
- Model 204 V2.1 or earlier
Description
IODEV specifies the input/output device type.
Valid settings of IODEV are:
IODEV | Access method/device type |
---|---|
1 | CCAIN/CCAPRINT (User 0 only) |
3 | BSAM (see Uses of IODEV=3 at Defining the user environment (CCAIN)) |
7 | SNA Communications Server 3270 |
11 | Remote User Language thread (full screen) |
19 | VTAM or TCP/IP (Horizon SQL thread) |
23 | Host Language IFAM thread |
25 | FUSI thread, new in version 7.6 of Model 204. These are created implicitly; as many threads are created as is the value of the FUNTSKN parameter. There is no reason to attempt to define these threads explicitly. |
27 | VTAM (Horizon thread) |
29 | Remote User Language thread (line-at-a-time) |
37 | SNA Communications Server 3767 and NTO (z/OS)
Note: Value 37 is no longer supported as of Model 204 version 7.6. |
39 | IUCV User Language thread (line-at-a-time) |
41 | IUCV User Language thread (full screen) |
43 | IUCV Host Language Interface thread |
45 | CMS line-at-a-time console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. |
47 | CMS full screen console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. |
49 | VTAM or TCP/IP Horizon Remote Command Line (RCL) thread. |
51 | SNA Communications Server (Parallel Query Option/204 thread) |
Note: In addition to the above table of valid settings of the IODEV parameter, the value of IODEV on some Model 204 threads can be set as a result of other parameters:
Parameter Recommended Meaning SDAEMDEV 15 IODEV number for Sdaemons TNDEV 21 IODEV number for TNSERV threads