TNDEV parameter: Difference between revisions

From m204wiki
Jump to navigation Jump to search
m (misc formatting)
Line 13: Line 13:
<dd><var class="product">[[Sirius Mods]]</var> 6.9
<dd><var class="product">[[Sirius Mods]]</var> 6.9
</dl>
</dl>
==Description==
==Description==
This parameter specifies the <var>[[IODEV_parameter|IODEV]]</var> number to be used for [[Janus_Telnet_Server|Janus Telnet Server]]
This parameter specifies the <var>[[IODEV parameter|IODEV]]</var> number to be used for [[Janus Telnet Server]] connections. When a connection is made to a Janus Telnet Server, the <var>IODEV</var> number
connections. When a connection is made to a Janus Telnet Server, the IODEV number
of the [[Sdaemons|Sdaemon]] thread is dynamically switched to the <var>TNDEV</var> value. If <var>TNDEV</var> is not
of the [[Sdaemons|SDAEMON]] thread is dynamically switched to the TNDEV value. If TNDEV is not
set to a non-zero value, no Janus Telnet Server (<var>TNSERV</var>) ports can be defined, and no telnet connections can be made directly to <var class="product">Model&nbsp;204</var>.
set to a non-zero value, no Janus Telnet Server (TNSERV) ports can be defined, and no
telnet connections can be made directly to <var class="product">Model 204</var>.
 
The value of the TNDEV parameter must be an odd number between 1 and 53, and it
must be different from the <var>[[Sdaemdev_parameter|SDAEMDEV]]</var> system parameter.


'''Note:''' No IODEV cards are allowed for the TNDEV IODEV number &#x2014; the IODEV
The value of the <var>TNDEV</var> parameter must be an odd number between 1 and 53, and it
number can only be used dynamically by Janus Telnet Server.
must be different from the <var>[[SDAEMDEV parameter|SDAEMDEV]]</var> system parameter.


The recommended setting for TNDEV is 21, an IODEV number no longer in use by
<p class="note">'''Note:''' No <var>IODEV</var> cards are allowed for <var>TNDEV</var>'s <var>IODEV</var> number &mdash; the <var>IODEV</var> number can only be used dynamically by Janus Telnet Server. </p>
<var class="product">Model 204</var>.


For more information about the Janus Telnet Server, see the'' Janus Sockets Reference
The recommended setting for <var>TNDEV</var> is 21, an <var>IODEV</var>  number no longer in use by <var class="product">Model&nbsp;204</var>.
Manual''.


[[Category:System parameters]]
[[Category:System parameters]]
[[Category:Parameters]]
[[Category:Parameters]]

Revision as of 16:48, 16 October 2017

IODEV number for TNSERV threads

Summary

Default value
0
Parameter type
System
Where set
User 0 CCAIN parameters
Related products
Janus Sockets
Introduced
Sirius Mods 6.9

Description

This parameter specifies the IODEV number to be used for Janus Telnet Server connections. When a connection is made to a Janus Telnet Server, the IODEV number of the Sdaemon thread is dynamically switched to the TNDEV value. If TNDEV is not set to a non-zero value, no Janus Telnet Server (TNSERV) ports can be defined, and no telnet connections can be made directly to Model 204.

The value of the TNDEV parameter must be an odd number between 1 and 53, and it must be different from the SDAEMDEV system parameter.

Note: No IODEV cards are allowed for TNDEV's IODEV number — the IODEV number can only be used dynamically by Janus Telnet Server.

The recommended setting for TNDEV is 21, an IODEV number no longer in use by Model 204.