IODEV parameter: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
Line 29: | Line 29: | ||
<tr><th align="right"><var>29</var></th><td>Remote User Language thread (line-at-a-time)</td></tr> | <tr><th align="right"><var>29</var></th><td>Remote User Language thread (line-at-a-time)</td></tr> | ||
<tr><th align="right"><var>37</var></th><td>SNA Communications Server 3767 and NTO (z/OS) | <tr><th align="right"><var>37</var></th><td>SNA Communications Server 3767 and NTO (z/OS) | ||
<p class="note"><b>Note:</b> Value 37 is | <p class="note"><b>Note:</b> Value 37 is obsolete as of Model 204 version 7.6.</p></td></tr> | ||
<tr><th align="right"><var>39</var></th><td>IUCV User Language thread (line-at-a-time)</td></tr> | <tr><th align="right"><var>39</var></th><td>IUCV User Language thread (line-at-a-time)</td></tr> | ||
<tr><th align="right"><var>41</var></th><td>IUCV User Language thread (full screen)</td></tr> | <tr><th align="right"><var>41</var></th><td>IUCV User Language thread (full screen)</td></tr> |
Revision as of 23:59, 27 January 2017
Type of I/O device
Summary
- Default value
- 1
- Parameter type
- User
- Where set
- On user's parameter line
- Related products
- All
- Introduced
- Model 204 V2.1 or earlier
Description
The input/output device type
Valid settings of IODEV are:
IODEV | Access method/device type |
---|---|
1 | CCAIN/CCAPRINT (User 0 only) |
3 | BSAM |
7 | SNA Communications Server 3270 |
11 | Remote User Language thread (full screen) |
19 | VTAM or TCP/IP (Horizon SQL thread) |
23 | Host Language IFAM thread |
25 | FUSI thread, new in version 7.6 of Model 204. These are created implicitly; as many threads are created as is the value of the FUNTSKN parameter. There is no reason to attempt to define these threads explicitly. |
27 | VTAM (Horizon thread) |
29 | Remote User Language thread (line-at-a-time) |
37 | SNA Communications Server 3767 and NTO (z/OS)
Note: Value 37 is obsolete as of Model 204 version 7.6. |
39 | IUCV User Language thread (line-at-a-time) |
41 | IUCV User Language thread (full screen) |
43 | IUCV Host Language Interface thread |
45 | CMS line-at-a-time console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. |
47 | CMS full screen console. This z/VM device setting is an ALTIODEV value; is cannot be specified on the user's parameter line. |
49 | VTAM or TCP/IP Horizon Remote Command Line (RCL) thread. |
51 | SNA Communications Server (Parallel Query Option/204 thread) |
Note: In addition to the above table of valid settings of the IODEV parameter, the value of IODEV on some Model 204 threads can be set as a result of other parameters:
Parameter Recommended Meaning SDAEMDEV 15 IODEV number for Sdaemons TNDEV 21 IODEV number for TNSERV threads